Customization: | Available |
---|---|
Breaking Capacity: | 12kv/24kv/40.5kv |
Type: | Current Fuse |
Still deciding? Get samples of US$ 30/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
(H) RW(F) series outdoor high voltage AC drop fuse, commonly referred to as the 'fuse', is expertly crafted to enhance the safety of outdoor overhead distribution systems. This essential safety component is built for systems with a rated frequency of 50Hz and a rated voltage of 10kV (12/15/35/40.5). Its primary role is to serve as a guardianship element for circuits or electrical apparatuses against overloads and short circuits within power systems. In normal operation, the fuse integrates seamlessly into power lines, maintaining a tensioned state with securely locked joints. Upon detecting a line fault, the surge of fault current prompts the fuse to melt, releasing the joint and swiftly disengaging the fuse tube, thus interrupting the circuit. This critical action ensures comprehensive safety and protection during equipment and line maintenance. The advanced load-type fuse enhances the standard variant by incorporating elastic contacts and an arc extinguishing cover, empowering it to adeptly manage the opening and closing of load currents within the power system.
This fuse adheres strictly to the stringent technical standards such as GB / T 15166.3 - 2008 for high voltage AC fuses, particularly Part 3: injection fuses, as well as DL / T 640 - 1997 standards for outdoor AC high voltage drop tested fuses and fuse links, ensuring optimal technical conditions for ordering.
Working Environment:
Ambient temperature: Crafted to withstand extremes, from a chilling -40°C to a warm +40°C;
Relative humidity: Designed to operate efficiently with a daily average not surpassing 95% and a monthly average not exceeding 90%;
Altitude compatibility: Robust performance guaranteed for altitudes up to 3000m;
Outdoor wind endurance: Engineered to withstand wind speeds up to 34 meters per second;
Prime Installation Site: Ideal for locations devoid of fire, explosion hazards, corrosive chemical gases, and ensuring superior ventilation.
Note: Should operational conditions exceed the aforementioned limits, clients are encouraged to engage in discussions with our company to explore tailored solutions.
Technical parameters
Note: At Beierbian Group Co., Ltd, we pride ourselves on our ability to customize products in accordance with specific user requirements.
Model |
Voltage |
Current |
Rated maximum
breaking current |
1min power frequency dry withstand
voltage |
1min power frequency wet withstand
voltage |
Rated lightning impulse withstand
voltage |
Opening and closing
load current |
XS-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
XS-15/100(200) |
15 |
||||||
PD-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
PD-15/100(200) |
15 |
||||||
(H)RW3-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW3-12/100(200) |
12 |
||||||
(H)RW4-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW4-12/100(200) |
12 |
||||||
(H)RW7-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW7-12/100(200) |
12 |
||||||
(H)RW10-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW10-12/100(200) |
12 |
||||||
(H)RW10-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)RW10-12F/100(200) |
12 |
||||||
(H)RW11-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
! |
(H)RW11-12/100(200) |
12 |
||||||
(H)RW11-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)RW11-12F/100(200) |
12 |
||||||
(H)RW12-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
45 |
30 |
105 |
/ |
(H)RW12-12/100(200) |
12 |
||||||
(H)RW12-15/100(200) |
15 |
||||||
(H)PRWG1-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)PRWG1-12F/100(200) |
12 |
||||||
(H)RW33-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW33-15/100(200) |
15 |
||||||
(H)RW5-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |
|||||||
(H)RW10-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |
|||||||
(H)PRWG2-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |