Customization: | Available |
---|---|
Breaking Capacity: | 12kv/24kv/40.5kv |
Type: | Current Fuse |
Still deciding? Get samples of US$ 30/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
(H) RW(F) series outdoor high voltage AC drop fuse, affectionately referred to as the "fuse," is meticulously engineered for outdoor overhead distribution systems operating at a graceful frequency of 50Hz, with a formidable rated voltage of 10kV (12/15/35/40.5). This fuse serves as a vigilant guardian, protecting circuits and electrical equipment from the menacing threats of overloads or short circuit faults within a power system. In normal operation, the fuse stands resolute, connected in series within the power line, maintaining a state of tension while the movable joint remains securely locked. However, when the line succumbs to failure, the fault current swiftly triggers the fuse to blow, unleashing a cascade of actions—the movable joint releases, and the fuse tube gracefully descends, severing the circuit's lifeline. This sequence of events ensures enhanced safety protection for both line and equipment maintenance. Elevating its functionality, the load type fuse incorporates an elastic contact, complemented by an innovative arc extinguishing cover, empowering it to adeptly open and close the load current within the power system.
The fuse adheres to stringent technical standards, including GB / T 15166.3 - 2008 high voltage AC fuses - Part 3: injection fuses, as well as DL / T 640 - 1997 outdoor AC high voltage drop tested fuses and fuse links ordering technical conditions, ensuring unparalleled reliability and performance.
Working Environment:
Ambient temperature: A resilient range from -40°C to +40°C;
Relative humidity: Ensures comfort with a daily average not exceeding 95%, and a monthly average not beyond 90%;
Aspirational altitude: Not to exceed a majestic 3000m;
Outdoor wind velocity: A gentle breeze, not surpassing 34 meters/second;
Installation site: Demands a sanctuary free from fire, explosion hazards, and corrosive chemical gases—ensuring a well-ventilated environment.
Note: Should these normal use conditions be surpassed, collaboration with our company is welcomed for tailored solutions.
Technical parameters
Note: Our esteemed company can cater to bespoke user requirements, delivering products tailored to your precise needs.
Model |
Voltage |
Current |
Rated maximum
breaking current |
1min power frequency dry withstand
voltage |
1min power frequency wet withstand
voltage |
Rated lightning impulse withstand
voltage |
Opening and closing
load current |
XS-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
XS-15/100(200) |
15 |
||||||
PD-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
PD-15/100(200) |
15 |
||||||
(H)RW3-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW3-12/100(200) |
12 |
||||||
(H)RW4-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW4-12/100(200) |
12 |
||||||
(H)RW7-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW7-12/100(200) |
12 |
||||||
(H)RW10-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW10-12/100(200) |
12 |
||||||
(H)RW10-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)RW10-12F/100(200) |
12 |
||||||
(H)RW11-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
! |
(H)RW11-12/100(200) |
12 |
||||||
(H)RW11-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)RW11-12F/100(200) |
12 |
||||||
(H)RW12-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
45 |
30 |
105 |
/ |
(H)RW12-12/100(200) |
12 |
||||||
(H)RW12-15/100(200) |
15 |
||||||
(H)PRWG1-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)PRWG1-12F/100(200) |
12 |
||||||
(H)RW33-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW33-15/100(200) |
15 |
||||||
(H)RW5-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |
|||||||
(H)RW10-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |
|||||||
(H)PRWG2-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |