Customization: | Available |
---|---|
Breaking Capacity: | 12kv/24kv/40.5kv |
Type: | Current Fuse |
Still deciding? Get samples of US$ 30/Piece
Order Sample
|
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() |
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
(H) RW(F) series outdoor high voltage AC drop fuse, a masterstroke of modern engineering, is a premier choice for outdoor overhead distribution networks operating at a frequency of 50Hz, with a formidable voltage range of 10kV (12/15/35/40.5). This indispensable fuse plays a crucial role in shielding circuits and electrical equipment from the dangers of overloads or short-circuit incidents within power systems. In regular use, it stays taut and firmly secured within the power line, ensuring unwavering connectivity. However, in the event of a fault, its intelligent design allows the fault current to blow the fuse, promptly triggering the release of the movable joint. This swift response ensures the fuse tube efficiently drops, guaranteeing the circuit is swiftly disconnected, thereby delivering essential safety protection during maintenance. Fortified with an elastic contact and an arc extinguishing cover, this load type fuse excels in skillfully managing the opening and closing of the load current within power systems.
Our fuse is a testament to precision engineering, crafted to meet stringent technical standards, including GB / T 15166.3 - 2008 for high voltage AC fuses, Part 3: injection fuses, and DL / T 640 - 1997 for outdoor AC high voltage drop tested fuses. These rigorous standards ensure outstanding performance and reliability under defined technical conditions.
Working Environment:
This product is expertly designed to operate within an extensive ambient temperature range, from a frosty -40°C to a warm +40°C, guaranteeing robust performance across various climates.
Boasting a tolerance for relative humidity where the daily average remains below 95% and the monthly average does not exceed 90%, this fuse is built to thrive in high humidity environments.
It is aptly suited for altitudes not exceeding 3000 meters, making it compatible with a multitude of geographical locations.
Skillfully engineered to withstand outdoor wind speeds reaching up to 34 meters per second, this fuse retains stability and functionality even in gusty conditions.
The installation site must be devoid of fire and explosion hazards, along with chemical corrosive gases, while also maintaining good ventilation to ensure peak performance and safety.
Note: If the standard normal use conditions are surpassed, we invite users to explore potential solutions with our company to maintain safety and efficiency.
Technical parameters
Note: We provide customizable solutions, tailoring products to meet the precise requirements of each user.
Model |
Voltage |
Current |
Rated maximum
breaking current |
1min power frequency dry withstand
voltage |
1min power frequency wet withstand
voltage |
Rated lightning impulse withstand
voltage |
Opening and closing
load current |
XS-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
XS-15/100(200) |
15 |
||||||
PD-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
PD-15/100(200) |
15 |
||||||
(H)RW3-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW3-12/100(200) |
12 |
||||||
(H)RW4-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW4-12/100(200) |
12 |
||||||
(H)RW7-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW7-12/100(200) |
12 |
||||||
(H)RW10-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW10-12/100(200) |
12 |
||||||
(H)RW10-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)RW10-12F/100(200) |
12 |
||||||
(H)RW11-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
! |
(H)RW11-12/100(200) |
12 |
||||||
(H)RW11-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)RW11-12F/100(200) |
12 |
||||||
(H)RW12-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
45 |
30 |
105 |
/ |
(H)RW12-12/100(200) |
12 |
||||||
(H)RW12-15/100(200) |
15 |
||||||
(H)PRWG1-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)PRWG1-12F/100(200) |
12 |
||||||
(H)RW33-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW33-15/100(200) |
15 |
||||||
(H)RW5-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |
|||||||
(H)RW10-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |
|||||||
(H)PRWG2-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |