(H) RW(F) series outdoor high voltage AC drop fuse (hereinafter referred to as the "fuse") is meticulously crafted for outdoor overhead distribution systems with a rated frequency of 50Hz and rated voltage of 10kV (12/15/35/40.5). This revolutionary fuse serves as the ultimate guardian for your circuit or electrical equipment, stepping in with precision during overload or short circuit situations within power systems. During normal operation, the fuse stands firm, seamlessly integrated into the power line, maintaining tension and securing the movable joint. In the event of a malfunction, the fault current triggers the fuse to blow, swiftly unlocking the movable joint, dropping the fuse tube, and effectively disconnecting the circuit. This process ensures optimal safety and protection for maintenance personnel and equipment. The load type fuse is ingeniously enhanced with elastic contact and an arc extinguishing cover, elevating its capability to adeptly manage load currents within the power system.
Our fuse is designed to adhere to rigorous technical standards such as GB / T 15166.3 - 2008 high voltage AC fuses - Part 3: injection fuses, DL / T 640 - 1997 outdoor AC high voltage drop tested fuses and fuse links ordering technical conditions, ensuring that each unit meets the highest quality criteria.
Ideal Working Environment:
Ambient temperature range is -40°C to +40°C, catering to diverse climate conditions;
Relative humidity parameters: a daily average not exceeding 95%, and a monthly average not surpassing 90%, offering dependable performance in varying humidity levels;
Suitable for altitudes up to 3000 meters, providing versatility in installation locations;
Capable of withstanding outdoor wind speeds up to 34 meters/second, ensuring durability even in windy conditions;
Installation Requirements: Select locations free from fire, explosion hazards, or chemical corrosive gases, and ensure a well-ventilated environment to maintain optimal performance.
Note: If the above normal use conditions are exceeded, we encourage users to engage in a consultation with Beierbian Group Co., Ltd. to explore customized solutions.
Technical Parameters
Note: Beierbian Group Co., Ltd. is pleased to offer products tailored to specific user requirements, ensuring a perfect fit for every unique application.
Model |
Voltage |
Current |
Rated maximum
breaking current |
1min power frequency dry withstand
voltage |
1min power frequency wet withstand
voltage |
Rated lightning impulse withstand
voltage |
Opening and closing
load current |
XS-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
XS-15/100(200) |
15 |
||||||
PD-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
PD-15/100(200) |
15 |
||||||
(H)RW3-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW3-12/100(200) |
12 |
||||||
(H)RW4-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW4-12/100(200) |
12 |
||||||
(H)RW7-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW7-12/100(200) |
12 |
||||||
(H)RW10-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW10-12/100(200) |
12 |
||||||
(H)RW10-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)RW10-12F/100(200) |
12 |
||||||
(H)RW11-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
! |
(H)RW11-12/100(200) |
12 |
||||||
(H)RW11-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)RW11-12F/100(200) |
12 |
||||||
(H)RW12-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
45 |
30 |
105 |
/ |
(H)RW12-12/100(200) |
12 |
||||||
(H)RW12-15/100(200) |
15 |
||||||
(H)PRWG1-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)PRWG1-12F/100(200) |
12 |
||||||
(H)RW33-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW33-15/100(200) |
15 |
||||||
(H)RW5-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |
|||||||
(H)RW10-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |
|||||||
(H)PRWG2-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |