(H) RW(F) series outdoor high voltage AC drop fuse, hereinafter referred to as the "fuse," is crafted for perfection in outdoor overhead distribution systems, boasting a rated frequency of 50Hz and a variable rated voltage of 10kV (12/15/35/40.5). This remarkable fuse stands as a stalwart protective component for circuits or electrical equipment, shielding against the perils of overload or short-circuit mishaps in power systems. Under routine operations, the fuse elegantly aligns in series with power lines, maintaining a poised tensioned state with a securely locked movable joint. Amidst line failures, the fault current orchestrates a precise blow of the fuse, gracefully releasing the movable joint, allowing the fuse tube to swiftly drop, and artfully severing the circuit. This action offers invaluable safety protection for the maintenance of lines and equipment. Enhanced with an elastic contact and an innovative arc extinguishing cover, the load type fuse elevates functionality beyond the ordinary, enabling seamless opening and closing of load currents within the power system.
Our fuses rigorously adhere to prestigious technical standards such as GB / T 15166.3 - 2008 for high voltage AC fuses - Part 3: injection fuses, and DL / T 640 - 1997 for outdoor AC high voltage drop tested fuses and fuse links ordering technical conditions, ensuring reliability and safety.
Optimal Working Environment:
Ambient temperature gracefully spans from -40°C to +40°C;
Relative humidity is meticulously regulated, maintaining a daily average not exceeding 95%, with a monthly average comfortably under 90%;
Perfectly suited for altitudes up to 3000 meters;
Designed to withstand outdoor wind speeds of up to 34 meters/second;
Installation site: Free from fire or explosion hazards, devoid of chemical corrosive gases, and ideally located in a well-ventilated environment.
Note: Should standard conditions extend beyond the aforementioned, bespoke solutions can be tailored through negotiation with our company.
Precise Technical Parameters
Note: Our company is poised to provide products meticulously customized to meet bespoke user requirements.
Model |
Voltage |
Current |
Rated maximum
breaking current |
1min power frequency dry withstand
voltage |
1min power frequency wet withstand
voltage |
Rated lightning impulse withstand
voltage |
Opening and closing
load current |
XS-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
XS-15/100(200) |
15 |
||||||
PD-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
PD-15/100(200) |
15 |
||||||
(H)RW3-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW3-12/100(200) |
12 |
||||||
(H)RW4-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW4-12/100(200) |
12 |
||||||
(H)RW7-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW7-12/100(200) |
12 |
||||||
(H)RW10-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW10-12/100(200) |
12 |
||||||
(H)RW10-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)RW10-12F/100(200) |
12 |
||||||
(H)RW11-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
! |
(H)RW11-12/100(200) |
12 |
||||||
(H)RW11-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)RW11-12F/100(200) |
12 |
||||||
(H)RW12-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
45 |
30 |
105 |
/ |
(H)RW12-12/100(200) |
12 |
||||||
(H)RW12-15/100(200) |
15 |
||||||
(H)PRWG1-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)PRWG1-12F/100(200) |
12 |
||||||
(H)RW33-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW33-15/100(200) |
15 |
||||||
(H)RW5-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |
|||||||
(H)RW10-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |
|||||||
(H)PRWG2-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |