Customization: | Available |
---|---|
Breaking Capacity: | 12kv/24kv/40.5kv |
Type: | Current Fuse |
Still deciding? Get samples of US$ 30/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
(H) RW(F) series outdoor high voltage AC drop fuse (referred to as "fuse") is an essential component for outdoor overhead distribution systems, designed to operate at a rated frequency of 50Hz and a rated voltage of 10kV (12/15/35/40.5). This crucial device serves as a protective agent for circuits or electrical equipment, effectively safeguarding against overload or short circuit failures within power systems. Under normal operations, the fuse is securely connected in series within the power line, maintaining a tight, tensioned state with its movable joint firmly locked. In the event of a line fault, the fault current triggers the fuse to blow, releasing the movable joint, allowing the fuse tube to swiftly drop and disconnecting the circuit. This swift action ensures superior safety protection, facilitating maintenance of the line and equipment with ease. Enhanced with innovative elastic contacts and an arc extinguishing cover, the load type fuse adeptly manages the opening and closing of load currents within the power system, elevating its reliability and functionality.
The fuse adheres to rigorous technical standards, including GB / T 15166.3 - 2008 for high voltage AC fuses - Part 3: injection fuses, as well as DL / T 640 - 1997 for outdoor AC high voltage drop tested fuses and fuse links ordering technical conditions. This compliance ensures it meets the highest benchmarks for quality and performance.
Working Environment:
Ambient temperature: Ranges from -40°C to +40°C; a robust performance across extreme weather conditions.
Relative humidity: Maintains durability with a daily average not exceeding 95%, and a monthly average not exceeding 90%;
Altitude: Operates efficiently at heights not surpassing 3000 meters;
Outdoor wind speed: Designed to withstand speeds up to 34 meters per second;
Installation site: Ideal for locations free from fire, explosion hazards, chemical corrosive gases, and well-ventilated environments, ensuring optimal safety.
Note: If conditions exceed normal operating parameters, customization is available through negotiation with the company, ensuring tailored solutions for unique requirements.
Technical Parameters
Note: Our company specializes in delivering customized products tailored to user specifications, ensuring the perfect fit for every need.
Model |
Voltage |
Current |
Rated maximum
breaking current |
1min power frequency dry withstand
voltage |
1min power frequency wet withstand
voltage |
Rated lightning impulse withstand
voltage |
Opening and closing
load current |
XS-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
XS-15/100(200) |
15 |
||||||
PD-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
PD-15/100(200) |
15 |
||||||
(H)RW3-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW3-12/100(200) |
12 |
||||||
(H)RW4-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW4-12/100(200) |
12 |
||||||
(H)RW7-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW7-12/100(200) |
12 |
||||||
(H)RW10-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW10-12/100(200) |
12 |
||||||
(H)RW10-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)RW10-12F/100(200) |
12 |
||||||
(H)RW11-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
! |
(H)RW11-12/100(200) |
12 |
||||||
(H)RW11-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)RW11-12F/100(200) |
12 |
||||||
(H)RW12-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
45 |
30 |
105 |
/ |
(H)RW12-12/100(200) |
12 |
||||||
(H)RW12-15/100(200) |
15 |
||||||
(H)PRWG1-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)PRWG1-12F/100(200) |
12 |
||||||
(H)RW33-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW33-15/100(200) |
15 |
||||||
(H)RW5-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |
|||||||
(H)RW10-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |
|||||||
(H)PRWG2-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |