Customization: | Available |
---|---|
Breaking Capacity: | 12kv/24kv/40.5kv |
Type: | Current Fuse |
Still deciding? Get samples of US$ 30/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
(H) RW(F) series outdoor high voltage AC drop fuse (hereinafter referred to as "fuse") is designed for excellence in safeguarding outdoor overhead distribution systems with a rated frequency of 50Hz and rated voltage of 10kV (12/15/35/40.5). As a protective stalwart, this fuse is crucial for circuits and electrical equipment, swiftly responding to overloads or short circuit faults in power systems. During regular operation, the fuse seamlessly integrates into the power line, maintaining a tensioned state with a securely locked movable joint. Upon detecting a line failure, the fault current instantly activates the fuse, releasing the joint, dropping the fuse tube, and promptly severing the circuit. This action ensures unparalleled safety and protection during the maintenance of lines and equipment. Enhanced with elastic contact and an arc extinguishing cover, the load type fuse adeptly manages load currents within the power system, offering an upgraded version of the standard type.
The fuse is crafted in strict conformity with leading technical standards, including GB / T 15166.3 - 2008 high voltage AC fuses - Part 3: injection fuses, and DL / T 640 - 1997 outdoor AC high voltage drop tested fuses and fuse links ordering technical conditions, ensuring high-quality performance and reliability.
Working Environment:
Ambient temperature: -40°C to +40°C; ensuring functionality in extreme climatic conditions.
Relative humidity: daily average does not exceed 95%, and the monthly average remains under 90%; providing robust performance in humid climates.
Altitude: Operational efficiency is maintained up to 3000m above sea level; ideal for high-altitude installations.
Outdoor wind speed: Sustains conditions with wind speeds not exceeding 34 meters/second; ensuring stability in windy environments.
Installation site: Designed for safe operation in locations free from fire, explosion hazards, chemical corrosive gases, and is well-ventilated.
Note: For conditions beyond those normally specified, customization is available through direct negotiation with our company, ensuring tailored solutions for unique circumstances.
Technical Parameters
Note: Our company is committed to customizing and supplying products that meet the specific needs of our clients.
Model |
Voltage |
Current |
Rated maximum
breaking current |
1min power frequency dry withstand
voltage |
1min power frequency wet withstand
voltage |
Rated lightning impulse withstand
voltage |
Opening and closing
load current |
XS-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
XS-15/100(200) |
15 |
||||||
PD-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
PD-15/100(200) |
15 |
||||||
(H)RW3-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW3-12/100(200) |
12 |
||||||
(H)RW4-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW4-12/100(200) |
12 |
||||||
(H)RW7-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW7-12/100(200) |
12 |
||||||
(H)RW10-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW10-12/100(200) |
12 |
||||||
(H)RW10-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)RW10-12F/100(200) |
12 |
||||||
(H)RW11-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
! |
(H)RW11-12/100(200) |
12 |
||||||
(H)RW11-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)RW11-12F/100(200) |
12 |
||||||
(H)RW12-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
45 |
30 |
105 |
/ |
(H)RW12-12/100(200) |
12 |
||||||
(H)RW12-15/100(200) |
15 |
||||||
(H)PRWG1-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)PRWG1-12F/100(200) |
12 |
||||||
(H)RW33-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW33-15/100(200) |
15 |
||||||
(H)RW5-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |
|||||||
(H)RW10-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |
|||||||
(H)PRWG2-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |