Outdoor High Voltage Isolation Switch with Load Break Disconnector

Product Details
Customization: Available
Type: 10kv/12kv/15kv
Structure: According to Customer Requirements
Still deciding? Get samples of $ !
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW PayPal
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

OEM Services
The supplier provides OEM services for popular brands
Quality Assurance
The supplier provides quality assurance
Private Mold
The supplier has private mold
Product Certification
The supplier's products already have relevant certification qualifications, including:
CE
to see all verified strength labels (20)
  • Outdoor High Voltage Isolation Switch with Load Break Disconnector
  • Outdoor High Voltage Isolation Switch with Load Break Disconnector
  • Outdoor High Voltage Isolation Switch with Load Break Disconnector
  • Outdoor High Voltage Isolation Switch with Load Break Disconnector
  • Outdoor High Voltage Isolation Switch with Load Break Disconnector
  • Outdoor High Voltage Isolation Switch with Load Break Disconnector
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Certifications
Overview

Basic Info.

Model NO.
(H)GWBEB
Installation
Outdoor High-voltage
Operation
Manual/Electric/Pneumatic/Hydraulic
Grounding Mode
According to Customer Requirements
Movement Mode
According to Customer Requirements
Number of Poles
According to Customer Requirements
Grounding
According to Customer Requirements
Series
Two
Run
According to Customer Requirements
Switching Mode
According to Customer Requirements
Common Model
Gw9
Structure of Operating
According to Customer Requirements
Certification
ISO, RoHS, CE
Brand
Chbeb
Customizable
OEM/According to Customer Requirements
Transport Package
Standard Shipping Packing
Specification
45*55*38mm
Trademark
CHBEB
Origin
China
HS Code
853530900
Production Capacity
5000 PCS/Quarter

Product Description

Outdoor High Voltage Isolation Switch with Load Break Disconnector
Product Description

Meet the (H)GWBEB type outdoor high-voltage isolation switch, also referred to as an isolation disconnect switch. This expertly crafted device is tailored for deployment on 10(12, 15, 24)kV high voltage power transmission and distribution lines. It proficiently manages the opening and closing of single-phase or three-phase circuits with the presence of voltage, yet without any load. Its design ensures optimal performance in a range of high-voltage scenarios.

Engineered for single-phase applications within three-phase line systems, this switch stands out for its uncomplicated structure, economic efficiency, and user-friendly operation. Available in rated currents of 200, 400, 600, 800, 1000, and 1250 amps, the switch is an assembly of a sturdy base, resilient post insulators, conductive components, and a mechanical section. It features a sophisticated gate knife structure for circuit operation, where each phase's gate knife includes two conductive blades, complemented by external compression springs on both sides. Adjustments to spring height ensure the precise contact pressure required for the gate knife's operation. The switch is manipulated through an insulated hook stick, providing seamless opening and closing actions, and a reliable self-locking mechanism ensures secure positioning.

Working Environment:

The altitude for operation should not surpass 1000 meters;

Ambient temperature parameters: A maximum temperature not exceeding +40°C, and a minimum threshold not dropping below -30°C;

Ensure that the outdoor wind speed remains within 35 meters/second;

The installation site must withstand seismic activities of no more than 8 degrees on the Richter scale, avoiding locations prone to frequent intense vibrations.

The chosen installation site should be devoid of gases, chemical deposits, salt mist, dust, dirt, or any other explosive or corrosive substances that could severely impact the switch's insulation and conductivity.

Note:

SHOULD THE NORMAL USE CONDITIONS EXCEED THE STATED PARAMETERS, USERS ARE ENCOURAGED TO ENGAGE IN DISCUSSIONS WITH THE COMPANY FOR ADJUSTMENTS.

Installation, Use and Adjustment

Pre-installation work

  1. Thoroughly cleanse the parts of any dust and dirt, and meticulously polish the surface of the insulating porcelain bottle for optimal performance.
  2. Ensure the wiring surface of the ground screw is thoroughly cleaned.
  3. Apply a protective layer of industrial Vaseline to both rotating components and contact areas to enhance durability.
  4. Inspect the contact surface and fine-tune the compression spring's height to ensure the contact pressure aligns with the specifications in Table II.
  5. This switch is meticulously designed for hoisting applications in conjunction with transformers along the line, ensuring seamless operational integration.
  6. With a rated current range of 200-400 ampere hours, the switch generally requires three mounting holes. For currents between 600-1000A, three mounting holes are also utilized for secure installation.

Conduct an annual inspection of the following components to ensure optimal functionality:
Cleanse dirt from conductive elements, contact surfaces, and the surfaces of insulating porcelain bottles for maintained efficiency.

Scrutinize all components for potential damage, placing particular emphasis on inspecting the insulating porcelain bottle for signs of damage or cracking.

Verify the integrity of the contact surface on the conductive component to maintain superior performance.


Outdoor High Voltage Isolation Switch with Load Break Disconnector

Detailed Photos

Outdoor High Voltage Isolation Switch with Load Break Disconnector
Outdoor High Voltage Isolation Switch with Load Break Disconnector
Outdoor High Voltage Isolation Switch with Load Break Disconnector
Outdoor High Voltage Isolation Switch with Load Break Disconnector


Outdoor High Voltage Isolation Switch with Load Break Disconnector
Outdoor High Voltage Isolation Switch with Load Break Disconnector

Outdoor High Voltage Isolation Switch with Load Break Disconnector
Outdoor High Voltage Isolation Switch with Load Break Disconnector
Outdoor High Voltage Isolation Switch with Load Break Disconnector
Outdoor High Voltage Isolation Switch with Load Break Disconnector
Outdoor High Voltage Isolation Switch with Load Break Disconnector
Outdoor High Voltage Isolation Switch with Load Break Disconnector
Outdoor High Voltage Isolation Switch with Load Break Disconnector
Outdoor High Voltage Isolation Switch with Load Break Disconnector
Outdoor High Voltage Isolation Switch with Load Break Disconnector
Outdoor High Voltage Isolation Switch with Load Break Disconnector
Outdoor High Voltage Isolation Switch with Load Break Disconnector
Outdoor High Voltage Isolation Switch with Load Break Disconnector

Product Parameters

The main technical parameters

Table I

Model

Rated voltage
kV

 

Rated current
A

kA

 

10 seconds thermal stable current
kA

peak

Valid values

 

(H)GW

 

10

12

15

200

5

9

5

400

21

15

10

600

35

25

14

630

35

25

14

800

35

25

14

1000

50

35

20

Contact force parameters

Table II

Model

Rated current(A)

contact pressure(kgf)

(H)GW

5

9

21

15

35

25

35

25

35

25

50

35

Certifications

Outdoor High Voltage Isolation Switch with Load Break DisconnectorOutdoor High Voltage Isolation Switch with Load Break Disconnector

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier