Customization: | Available |
---|---|
Breaking Capacity: | 12kv/24kv/40.5kv |
Type: | Current Fuse |
Still deciding? Get samples of US$ 30/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
(H) RW(F) series outdoor high voltage AC drop fuse, henceforth referred to as the 'fuse', is expertly designed for outdoor overhead distribution systems, offering a rated frequency of 50Hz and a versatile rated voltage of 10kV(12/15/35/40.5). This cutting-edge protective element shields circuits or electrical devices against overloads or short circuit faults within power systems. Under normal operations, the fuse, being in a tensioned state, is seamlessly integrated into the power line, while the movable joint remains securely locked. Should a failure occur, the fault current triggers the fuse to blow, releasing the movable joint and swiftly dropping the fuse tube, thereby instantly interrupting the circuit. This process is vital for the safety and maintenance of lines and equipment. Enhancing the load type fuse, we've incorporated elastic contact and an advanced arc extinguishing cover based on the standard model, allowing for efficient opening and closing of the load current within the power system.
Our fuses rigorously adhere to top-tier technical standards including GB / T 15166.3 - 2008 for high voltage AC fuses - Part 3: injection fuses, and DL / T 640 - 1997, which outline the ordering technical conditions for outdoor AC high voltage drop tested fuses and fuse links.
Working Environment:
Ambient temperature ranges from a chilling -40°C to a warm +40°C;
Relative humidity is meticulously regulated, with the daily average not surpassing 95%, and the monthly average staying below 90%;
The operational altitude is capped at 3000 meters;
Outdoor wind velocities must not exceed a swift 34 meters/second;
Installation site requirements include an area free from fire, explosion hazards, chemical corrosive gases, and must be well-ventilated.
Note: Should your use conditions exceed the above specifications, we welcome discussions to tailor solutions to your needs.
Technical parameters
Note: We are committed to delivering products that meet your precise requirements. Please reach out for custom solutions.
Model |
Voltage |
Current |
Rated maximum
breaking current |
1min power frequency dry withstand
voltage |
1min power frequency wet withstand
voltage |
Rated lightning impulse withstand
voltage |
Opening and closing
load current |
XS-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
XS-15/100(200) |
15 |
||||||
PD-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
PD-15/100(200) |
15 |
||||||
(H)RW3-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW3-12/100(200) |
12 |
||||||
(H)RW4-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW4-12/100(200) |
12 |
||||||
(H)RW7-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW7-12/100(200) |
12 |
||||||
(H)RW10-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW10-12/100(200) |
12 |
||||||
(H)RW10-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)RW10-12F/100(200) |
12 |
||||||
(H)RW11-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
! |
(H)RW11-12/100(200) |
12 |
||||||
(H)RW11-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)RW11-12F/100(200) |
12 |
||||||
(H)RW12-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
45 |
30 |
105 |
/ |
(H)RW12-12/100(200) |
12 |
||||||
(H)RW12-15/100(200) |
15 |
||||||
(H)PRWG1-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)PRWG1-12F/100(200) |
12 |
||||||
(H)RW33-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW33-15/100(200) |
15 |
||||||
(H)RW5-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |
|||||||
(H)RW10-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |
|||||||
(H)PRWG2-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |