Customization: | Available |
---|---|
Breaking Capacity: | 12kv/24kv/40.5kv |
Type: | Current Fuse |
Still deciding? Get samples of US$ 30/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
The (H) RW(F) series outdoor high voltage AC drop fuse, hereafter referred to as the 'fuse', is expertly designed for outdoor overhead distribution systems. It operates at a rated frequency of 50Hz, with a versatile rated voltage range of 10kV (12/15/35/40.5). Functioning as a critical safety device, it serves to protect circuits and electrical equipment from overload or short circuit incidents in power systems. In standard operation, the fuse remains in a tensioned state, safely locked in series within the power line. Upon detecting a fault, the fault current triggers the fuse to blow, releasing the movable joint swiftly, dropping the fuse tube, and effectively cutting off the circuit. This mechanism ensures robust protection for line and equipment maintenance. Enhanced with elastic contact and an arc extinguishing cover, this load type fuse excels in opening and closing load currents within the power system.
The fuse adheres to stringent technical standards, including GB/T 15166.3 - 2008 for high voltage AC fuses, Part 3: injection fuses, as well as DL/T 640 - 1997 for outdoor AC high voltage drop tested fuses and fuse links ordering technical conditions, ensuring superior quality and reliability.
Working Environment:
Designed to withstand varying conditions, the ambient temperature for optimal operation ranges from -40°C to +40°C.
The fuse is engineered to function efficiently even in high humidity, with a daily average relative humidity not exceeding 95% and a monthly average not exceeding 90%.
Ideal for high-altitude applications, the operational altitude should not exceed 3000 meters.
Built to endure environmental challenges, it can withstand outdoor wind speeds up to 34 meters per second.
Installation is recommended in sites free from fire, explosion hazards, and corrosive chemical gases, ensuring a well-ventilated environment for optimal performance.
Note: For conditions outside these standard parameters, users are encouraged to consult with our company to discuss potential custom solutions.
Technical parameters
Note: To meet specific requirements, our company offers the flexibility to supply custom products tailored to user specifications.
Model |
Voltage |
Current |
Rated maximum
breaking current |
1min power frequency dry withstand
voltage |
1min power frequency wet withstand
voltage |
Rated lightning impulse withstand
voltage |
Opening and closing
load current |
XS-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
XS-15/100(200) |
15 |
||||||
PD-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
PD-15/100(200) |
15 |
||||||
(H)RW3-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW3-12/100(200) |
12 |
||||||
(H)RW4-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW4-12/100(200) |
12 |
||||||
(H)RW7-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW7-12/100(200) |
12 |
||||||
(H)RW10-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW10-12/100(200) |
12 |
||||||
(H)RW10-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)RW10-12F/100(200) |
12 |
||||||
(H)RW11-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
! |
(H)RW11-12/100(200) |
12 |
||||||
(H)RW11-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)RW11-12F/100(200) |
12 |
||||||
(H)RW12-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
45 |
30 |
105 |
/ |
(H)RW12-12/100(200) |
12 |
||||||
(H)RW12-15/100(200) |
15 |
||||||
(H)PRWG1-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)PRWG1-12F/100(200) |
12 |
||||||
(H)RW33-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW33-15/100(200) |
15 |
||||||
(H)RW5-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |
|||||||
(H)RW10-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |
|||||||
(H)PRWG2-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |