Load Break Disconnector for High Voltage Outdoor Use with Custom Specs

Product Details
Customization: Available
Type: 10kv/12kv/15kv
Structure: According to Customer Requirements
Still deciding? Get samples of $ !
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

OEM Services
The supplier provides OEM services for popular brands
Quality Assurance
The supplier provides quality assurance
Private Mold
The supplier has private mold
Product Certification
The supplier's products already have relevant certification qualifications, including:
CE
to see all verified strength labels (20)
  • Load Break Disconnector for High Voltage Outdoor Use with Custom Specs
  • Load Break Disconnector for High Voltage Outdoor Use with Custom Specs
  • Load Break Disconnector for High Voltage Outdoor Use with Custom Specs
  • Load Break Disconnector for High Voltage Outdoor Use with Custom Specs
  • Load Break Disconnector for High Voltage Outdoor Use with Custom Specs
  • Load Break Disconnector for High Voltage Outdoor Use with Custom Specs
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Certifications
Overview

Basic Info.

Model NO.
(H)GWBEB
Installation
Outdoor High-voltage
Operation
Manual/Electric/Pneumatic/Hydraulic
Grounding Mode
According to Customer Requirements
Movement Mode
According to Customer Requirements
Number of Poles
According to Customer Requirements
Grounding
According to Customer Requirements
Series
Two
Run
According to Customer Requirements
Switching Mode
According to Customer Requirements
Common Model
Gw9
Structure of Operating
According to Customer Requirements
Certification
ISO, RoHS, CE
Brand
Chbeb
Customizable
OEM/According to Customer Requirements
Transport Package
Standard Shipping Packing
Specification
45*55*38mm
Trademark
CHBEB
Origin
China
HS Code
853530900
Production Capacity
5000 PCS/Quarter

Product Description

Load Break Disconnector for High Voltage Outdoor Use with Custom Specs
Product Description

Introducing the (H)GWBEB type outdoor high-voltage isolation switch, an essential component in modern power systems. Commonly referred to as an isolation disconnect switch, this device is expertly engineered for seamless operation on 10(12, 15, 24)kV high voltage transmission and distribution lines, making it ideal for opening and closing circuits—single-phase or three-phase—without load but with voltage present. Its robust design ensures reliability and safety in critical applications.

Designed for single-phase operations within three-phase systems, this switch stands out for its straightforward structure, cost-efficiency, and user-friendly interface. With available rated currents of 200, 400, 600, 800, 1000, and 1250 amps, it is adaptable to various needs. Its components include a sturdy base, durable post insulators, high-quality conductive elements, and a reliable mechanical section. The innovative gate knife mechanism enables efficient circuit control, featuring dual conductive blades and external compression springs for optimal contact pressure, easily adjustable by spring height. Operate this switch smoothly with an insulated hook stick, and rely on its secure self-locking device for safe usage.

Working Environment:

Designed for altitudes not exceeding 1000 meters;

Functions efficiently within a temperature range: maximum of +40°C and a minimum of -30°C;

Built to withstand outdoor wind speeds up to 35 meters/second;

Seismic intensity tolerance up to 8 degrees; the installation site should be free from frequent severe vibrations to ensure stability.

Installation sites must remain free of gases, chemical deposits, salt mist, dust, dirt, or any other explosive or corrosive environments that could compromise the switch's insulation and conductivity.

Note:

WHEN STANDARD USE CONDITIONS ARE EXCEEDED, USERS ARE ENCOURAGED TO DISCUSS SPECIFIC REQUIREMENTS WITH THE COMPANY. CUSTOM SOLUTIONS MAY BE AVAILABLE.

Installation, Use, and Adjustment

Pre-installation work

  1. Thoroughly clean parts from dust and dirt, and carefully polish the insulating porcelain bottle surface to maintain optimal performance.
  2. Ensure the wiring surface of the ground screw is impeccably scrubbed for secure connections.
  3. Apply a protective layer of industrial Vaseline on rotating parts and contact areas to ensure smooth operation.
  4. Inspect the contact surface and adjust the compression spring height to achieve the perfect contact pressure as per Table II specifications.
  5. This switch is engineered exclusively for hoisting applications and is designed to work in harmony with the transformer on the line.
  6. The switch, with a rated current of 200-400 ampere hours, typically requires only three mounting holes, while 600-1000A use three mounting holes for secure installation.

Annual Maintenance Checklist: Regularly inspect these vital components to ensure long-lasting functionality.
Meticulously clean dirt from conductive parts, contact surfaces, and insulating porcelain bottle surfaces to maintain conductive integrity.

Inspect all components for potential damage, with particular attention to the insulating porcelain bottle for any signs of damage or cracks.

Verify that the contact surface of the conductive part remains in excellent condition for consistent performance.


Load Break Disconnector for High Voltage Outdoor Use with Custom Specs

Detailed Photos

Load Break Disconnector for High Voltage Outdoor Use with Custom Specs
Load Break Disconnector for High Voltage Outdoor Use with Custom Specs
Load Break Disconnector for High Voltage Outdoor Use with Custom Specs
Load Break Disconnector for High Voltage Outdoor Use with Custom Specs


Load Break Disconnector for High Voltage Outdoor Use with Custom Specs
Load Break Disconnector for High Voltage Outdoor Use with Custom Specs

Load Break Disconnector for High Voltage Outdoor Use with Custom Specs
Load Break Disconnector for High Voltage Outdoor Use with Custom Specs
Load Break Disconnector for High Voltage Outdoor Use with Custom Specs
Load Break Disconnector for High Voltage Outdoor Use with Custom Specs
Load Break Disconnector for High Voltage Outdoor Use with Custom Specs
Load Break Disconnector for High Voltage Outdoor Use with Custom Specs
Load Break Disconnector for High Voltage Outdoor Use with Custom Specs
Load Break Disconnector for High Voltage Outdoor Use with Custom Specs
Load Break Disconnector for High Voltage Outdoor Use with Custom Specs
Load Break Disconnector for High Voltage Outdoor Use with Custom Specs
Load Break Disconnector for High Voltage Outdoor Use with Custom Specs
Load Break Disconnector for High Voltage Outdoor Use with Custom Specs

Product Parameters

The main technical parameters

Table I

Model

Rated voltage
kV

 

Rated current
A

kA

 

10 seconds thermal stable current
kA

peak

Valid values

 

(H)GW

 

10

12

15

200

5

9

5

400

21

15

10

600

35

25

14

630

35

25

14

800

35

25

14

1000

50

35

20

Contact force parameters

Table II

Model

Rated current(A)

contact pressure(kgf)

(H)GW

5

9

21

15

35

25

35

25

35

25

50

35

Certifications

Load Break Disconnector for High Voltage Outdoor Use with Custom SpecsLoad Break Disconnector for High Voltage Outdoor Use with Custom Specs

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier