High Voltage Load Break Disconnector with Outdoor Isolation Switch Function

Product Details
Customization: Available
Type: 10kv/12kv/15kv
Structure: According to Customer Requirements
Still deciding? Get samples of US$ 140/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

OEM Services
The supplier provides OEM services for popular brands
Quality Assurance
The supplier provides quality assurance
Private Mold
The supplier has private mold
Product Certification
The supplier's products already have relevant certification qualifications, including:
CE
to see all verified strength labels (20)
  • High Voltage Load Break Disconnector with Outdoor Isolation Switch Function
  • High Voltage Load Break Disconnector with Outdoor Isolation Switch Function
  • High Voltage Load Break Disconnector with Outdoor Isolation Switch Function
  • High Voltage Load Break Disconnector with Outdoor Isolation Switch Function
  • High Voltage Load Break Disconnector with Outdoor Isolation Switch Function
  • High Voltage Load Break Disconnector with Outdoor Isolation Switch Function
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Certifications
Overview

Basic Info.

Model NO.
(H)GWBEB
Installation
Outdoor High-voltage
Operation
Manual/Electric/Pneumatic/Hydraulic
Grounding Mode
According to Customer Requirements
Movement Mode
According to Customer Requirements
Number of Poles
According to Customer Requirements
Grounding
According to Customer Requirements
Series
Two
Run
According to Customer Requirements
Switching Mode
According to Customer Requirements
Common Model
Gw9
Structure of Operating
According to Customer Requirements
Certification
ISO, RoHS, CE
Brand
Chbeb
Customizable
OEM/According to Customer Requirements
Transport Package
Standard Shipping Packing
Specification
45*55*38mm
Trademark
CHBEB
Origin
China
HS Code
853530900
Production Capacity
5000 PCS/Quarter

Product Description

High Voltage Load Break Disconnector with Outdoor Isolation Switch Function
Product Description

Introducing the (H)GWBEB type outdoor high-voltage isolation switch, a cutting-edge solution for managing voltage on your power transmission and distribution lines. This versatile isolation disconnect switch is specifically engineered for 10(12, 15, 24)kV high voltage systems, seamlessly opening and closing both single-phase and three-phase circuits. It operates efficiently without a load, ensuring voltage is always present, making it the perfect choice for modern infrastructure.

Experience innovation with our switch designed for single-phase operation within three-phase line systems. Renowned for its simplicity, affordability, and user-friendly nature, it accommodates rated currents of 200, 400, 600, 800, 1000, and 1250 amps. The switch is meticulously crafted, comprising a robust base, durable post insulators, efficient conductive parts, and a reliable mechanical section. Our unique gate knife structure is employed for circuit operations, with each phase fortified by two conductive blades and external compression springs. Adjust the spring height effortlessly for optimal contact pressure. Operate the switch smoothly using an insulated hook stick, enhanced with a secure self-locking feature for added safety.

Working Environment:

Ideal for altitudes not exceeding 1000 meters;

Ambient temperature range: a maximum of +40°C and a minimum of -30°C;

Designed to withstand outdoor wind speeds up to 35 meters/second;

Built to endure seismic intensities up to 8 degrees; installation sites should be free from frequent severe vibrations.

Installation sites must be devoid of gases, chemical deposits, salt mist, dust, dirt, or any explosive or corrosive substances that could compromise the switch's insulation and conductivity.

Note:

WHEN CONDITIONS BEYOND NORMAL USE ARISE, CUSTOMERS ARE WELCOME TO NEGOTIATE SPECIFIC REQUIREMENTS WITH THE COMPANY.

 

Installation, Use and Adjustment

Pre-installation work

  1. Ensure optimal performance by meticulously cleaning all components. Remove dust and dirt, and gently wipe the surface of each insulating porcelain bottle.
  2. Thoroughly clean the wiring surface of the ground screw to ensure excellent connectivity.
  3. Apply a protective layer of industrial Vaseline on rotating parts and contact areas to maintain smooth operations.
  4. Inspect the contact surface and adjust the compression spring height to guarantee the contact pressure aligns with the specifications in Table II.
  5. This switch is designed exclusively for hoisting applications, working in harmony with transformers on the line for unparalleled efficiency.
  6. For rated currents of 200-400 ampere hours, typically three mounting holes are utilized. For 600-1000A, three mounting holes provide stable installation.

Conduct an annual inspection of the following switch components to ensure longevity and reliability:
Thoroughly clean conductive parts, contact surfaces, and insulating porcelain bottles to remove any accumulated dirt.

Inspect all components for potential damage, giving special attention to examining insulating porcelain bottles for any signs of cracks or damages.

Verify that the contact surfaces of conductive parts remain intact and effective.


High Voltage Load Break Disconnector with Outdoor Isolation Switch Function

Detailed Photos

 

High Voltage Load Break Disconnector with Outdoor Isolation Switch Function
High Voltage Load Break Disconnector with Outdoor Isolation Switch Function
High Voltage Load Break Disconnector with Outdoor Isolation Switch Function
High Voltage Load Break Disconnector with Outdoor Isolation Switch Function


High Voltage Load Break Disconnector with Outdoor Isolation Switch Function
High Voltage Load Break Disconnector with Outdoor Isolation Switch Function

High Voltage Load Break Disconnector with Outdoor Isolation Switch Function
High Voltage Load Break Disconnector with Outdoor Isolation Switch Function
High Voltage Load Break Disconnector with Outdoor Isolation Switch Function
High Voltage Load Break Disconnector with Outdoor Isolation Switch Function
High Voltage Load Break Disconnector with Outdoor Isolation Switch Function
High Voltage Load Break Disconnector with Outdoor Isolation Switch Function
High Voltage Load Break Disconnector with Outdoor Isolation Switch Function
High Voltage Load Break Disconnector with Outdoor Isolation Switch Function
High Voltage Load Break Disconnector with Outdoor Isolation Switch Function
High Voltage Load Break Disconnector with Outdoor Isolation Switch Function
High Voltage Load Break Disconnector with Outdoor Isolation Switch Function
High Voltage Load Break Disconnector with Outdoor Isolation Switch Function

 

Product Parameters

The main technical parameters

Table I

Model

Rated voltage
kV

 

Rated current
A

kA

 

10 seconds thermal stable current
kA

peak

Valid values

 

(H)GW

 

10

12

15

200

5

9

5

400

21

15

10

600

35

25

14

630

35

25

14

800

35

25

14

1000

50

35

20

Contact force parameters

Table II

Model

Rated current(A)

contact pressure(kgf)

(H)GW

5

9

21

15

35

25

35

25

35

25

50

35

Certifications

High Voltage Load Break Disconnector with Outdoor Isolation Switch FunctionHigh Voltage Load Break Disconnector with Outdoor Isolation Switch Function

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier