Customization: | Available |
---|---|
Breaking Capacity: | 12kv/24kv/40.5kv |
Type: | Current Fuse |
Still deciding? Get samples of US$ 30/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
(H) RW(F) series outdoor high voltage AC drop fuse, referred to as the 'fuse', is expertly designed for outdoor overhead distribution systems. With a rated frequency of 50Hz and voltage levels of 10kV (12/15/35/40.5), this fuse acts as an indispensable protective component against overload or short circuit faults in power systems. Seamlessly integrated in series in the power line, it maintains a tensioned state with a locked movable joint under normal conditions. In the event of a line fault, the fault current triggers the fuse to blow, releasing the joint and swiftly dropping the fuse tube to interrupt the circuit, thus safeguarding the line and equipment maintenance. The load type fuse enhances the ordinary model with elastic contacts and an arc extinguishing cover, allowing proficient opening and closing of the load current within power systems.
The fuse is crafted to meet rigorous technical standards, including GB / T 15166.3 - 2008 High Voltage AC Fuses - Part 3: Injection Fuses, and DL / T 640 - 1997 Outdoor AC High Voltage Drop Tested Fuses. These standards ensure compliance with fuse links ordering technical conditions, affirming reliability and top-tier performance.
Working Environment:
Ambient temperature: -40°C to +40°C;
Relative humidity: daily average not exceeding 95%, monthly average not exceeding 90%;
Altitude tolerance up to 3000 meters;
Outdoor wind speed should not exceed 34 meters/second;
Installation site: Free from fire, explosion hazards, chemical corrosive gases, and should be well-ventilated.
Note: Should the standard conditions of use be surpassed, users are encouraged to engage in discussions with the company for tailored solutions.
Technical Parameters
Note: Beierbian Group Co., Ltd is committed to catering to user needs by offering customized product solutions.
Model |
Voltage |
Current |
Rated maximum
breaking current |
1min power frequency dry withstand
voltage |
1min power frequency wet withstand
voltage |
Rated lightning impulse withstand
voltage |
Opening and closing
load current |
XS-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
XS-15/100(200) |
15 |
||||||
PD-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
PD-15/100(200) |
15 |
||||||
(H)RW3-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW3-12/100(200) |
12 |
||||||
(H)RW4-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW4-12/100(200) |
12 |
||||||
(H)RW7-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW7-12/100(200) |
12 |
||||||
(H)RW10-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW10-12/100(200) |
12 |
||||||
(H)RW10-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)RW10-12F/100(200) |
12 |
||||||
(H)RW11-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
! |
(H)RW11-12/100(200) |
12 |
||||||
(H)RW11-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)RW11-12F/100(200) |
12 |
||||||
(H)RW12-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
45 |
30 |
105 |
/ |
(H)RW12-12/100(200) |
12 |
||||||
(H)RW12-15/100(200) |
15 |
||||||
(H)PRWG1-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)PRWG1-12F/100(200) |
12 |
||||||
(H)RW33-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW33-15/100(200) |
15 |
||||||
(H)RW5-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |
|||||||
(H)RW10-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |
|||||||
(H)PRWG2-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |