Customization: | Available |
---|---|
Breaking Capacity: | 12kv/24kv/40.5kv |
Type: | Current Fuse |
Still deciding? Get samples of US$ 30/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
(H) RW(F) series outdoor high voltage AC drop fuse, affectionately known as the "fuse," is a vital component engineered for outdoor overhead distribution systems operating at a standard frequency of 50Hz and a rated voltage of 10kV (12/15/35/40.5). This sophisticated device provides a trustworthy line of defense for circuits and electrical equipment, stepping in heroically during overloads or short circuit occurrences. Seamlessly integrated into the power line, the fuse is perpetually poised and secure, ensuring constant readiness. In the event of a line malfunction, the surge of fault current initiates a rapid response: the fuse surrenders, liberating the joint, instantaneously dropping the fuse tube, and halting the circuit to ensure the utmost safety. For enhanced performance, the load type fuse is innovatively equipped with elastic contacts and an arc extinguishing cover, granting it the capability to manage load currents adeptly.
Our fuses are meticulously crafted to align with premier technical standards, including GB / T 15166.3 - 2008, which pertains to high voltage AC fuses, specifically Part 3: injection fuses, as well as DL / T 640 - 1997, which outlines the specifications for outdoor AC high voltage drop-tested fuses and fuse links. These rigorous standards ensure the reliability and efficiency of our products under the stipulated technical conditions.
Working Environment:
Ambient temperature: Ranging from the frigid chill of -40°C to the warmth of +40°C;
Relative humidity: Daily levels should not surpass 95%, while monthly averages should remain below 90%;
Ensure installation at altitudes not exceeding 3000 meters;
Outdoor wind velocity: Must be maintained below 34 meters per second;
Installation site: Select a location free from fire or explosion hazards, devoid of chemically corrosive gases, and ensure it is well-ventilated.
Note: If conditions deviate beyond these standard parameters, consultation with our company is recommended to discuss potential accommodations.
Technical Parameters
Note: Our company offers the flexibility to tailor products to meet specific user requirements.
Model |
Voltage |
Current |
Rated maximum
breaking current |
1min power frequency dry withstand
voltage |
1min power frequency wet withstand
voltage |
Rated lightning impulse withstand
voltage |
Opening and closing
load current |
XS-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
XS-15/100(200) |
15 |
||||||
PD-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
PD-15/100(200) |
15 |
||||||
(H)RW3-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW3-12/100(200) |
12 |
||||||
(H)RW4-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW4-12/100(200) |
12 |
||||||
(H)RW7-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW7-12/100(200) |
12 |
||||||
(H)RW10-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW10-12/100(200) |
12 |
||||||
(H)RW10-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)RW10-12F/100(200) |
12 |
||||||
(H)RW11-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
! |
(H)RW11-12/100(200) |
12 |
||||||
(H)RW11-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)RW11-12F/100(200) |
12 |
||||||
(H)RW12-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
45 |
30 |
105 |
/ |
(H)RW12-12/100(200) |
12 |
||||||
(H)RW12-15/100(200) |
15 |
||||||
(H)PRWG1-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)PRWG1-12F/100(200) |
12 |
||||||
(H)RW33-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW33-15/100(200) |
15 |
||||||
(H)RW5-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |
|||||||
(H)RW10-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |
|||||||
(H)PRWG2-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |