Customization: | Available |
---|---|
Breaking Capacity: | 12kv/24kv/40.5kv |
Type: | Current Fuse |
Still deciding? Get samples of US$ 30/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
(H) RW(F) Series Outdoor High Voltage AC Drop Fuse – An essential safeguard for your outdoor overhead distribution systems, operating at a rated frequency of 50Hz and rated voltage of 10kV (12/15/35/40.5). This fuse acts as a vital protective component for circuits or electrical equipment, effectively mitigating overloads or short circuit faults within power systems. Under normal conditions, the fuse maintains a series connection in the power line, remaining tensioned and lock-secured. Upon encountering a fault, the resultant fault current triggers the fuse to rupture, releasing the movable joint, swiftly lowering the fuse tube, thereby disconnecting the circuit. This mechanism ensures superior safety protection for maintaining both line and equipment integrity. Enhanced with an elastic contact and an arc extinguishing cover, the load type fuse is adept at handling and facilitating the open and close operations of the load current within power systems.
Our fuses are crafted to align with stringent technical standards, including GB/T 15166.3 - 2008 'High Voltage AC Fuses - Part 3: Injection Fuses', and DL/T 640 - 1997 'Outdoor AC High Voltage Drop Tested Fuses and Fuse Links Ordering Technical Conditions', ensuring reliability and top-tier performance.
Optimal Operating Environment:
The ambient temperature range is a robust -40°C to +40°C;
Maintained relative humidity with a daily average not exceeding 95% and a monthly average below 90%;
Operation is optimal at altitudes up to 3000 meters;
Designed to withstand outdoor wind speeds of up to 34 meters per second;
Installation should be conducted in areas devoid of fire, explosion hazards, chemical corrosive gases, and should ensure adequate ventilation.
Special Note: If operational conditions surpass the stated norms, users are encouraged to engage in discussions with our company for tailored solutions.
Technical Specifications
Please note: We offer customization of products to meet specific user demands.
Model |
Voltage |
Current |
Rated maximum
breaking current |
1min power frequency dry withstand
voltage |
1min power frequency wet withstand
voltage |
Rated lightning impulse withstand
voltage |
Opening and closing
load current |
XS-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
XS-15/100(200) |
15 |
||||||
PD-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
PD-15/100(200) |
15 |
||||||
(H)RW3-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW3-12/100(200) |
12 |
||||||
(H)RW4-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW4-12/100(200) |
12 |
||||||
(H)RW7-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW7-12/100(200) |
12 |
||||||
(H)RW10-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW10-12/100(200) |
12 |
||||||
(H)RW10-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)RW10-12F/100(200) |
12 |
||||||
(H)RW11-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
! |
(H)RW11-12/100(200) |
12 |
||||||
(H)RW11-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)RW11-12F/100(200) |
12 |
||||||
(H)RW12-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
45 |
30 |
105 |
/ |
(H)RW12-12/100(200) |
12 |
||||||
(H)RW12-15/100(200) |
15 |
||||||
(H)PRWG1-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)PRWG1-12F/100(200) |
12 |
||||||
(H)RW33-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW33-15/100(200) |
15 |
||||||
(H)RW5-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |
|||||||
(H)RW10-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |
|||||||
(H)PRWG2-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |