Customization: | Available |
---|---|
Breaking Capacity: | 12kv/24kv/40.5kv |
Type: | Current Fuse |
Still deciding? Get samples of US$ 30/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
(H) RW(F) Series Outdoor High Voltage AC Drop Fuse (hereinafter referred to as "fuse") is the pinnacle of protection for outdoor overhead distribution systems operating with a rated frequency of 50Hz and a rated voltage of 10kV (12/15/35/40.5kV). This fuse stands as a stalwart guardian, designed to safeguard circuits and electrical equipment from the perils of overload or short circuit faults. Seamlessly integrated into power lines, the fuse maintains a tensioned position with its movable joint securely locked during normal operations. Upon detecting a fault, the fault current triggers the fuse to blow, releasing the movable joint, swiftly dropping the fuse tube to disconnect the circuit, ensuring the ultimate safety of line and equipment maintenance. Enhanced with elastic contact and an arc extinguishing cover, this load type fuse elevates the standard by efficiently opening and closing the load current within the power system.
The fuse adheres to rigorous technical benchmarks such as GB/T 15166.3 - 2008, covering high voltage AC fuses - Part 3: injection fuses, and DL/T 640 - 1997, which outlines the ordering technical conditions for outdoor AC high voltage drop tested fuses and fuse links.
Working Environment:
Ambient temperature: -40°C to +40°C, offering resilience across a broad thermal range;
Relative humidity: daily average not exceeding 95%, while maintaining a monthly average under 90%;
Functionality assured at altitudes up to 3000 meters;
Sustains outdoor wind speeds up to 34 meters per second without compromise;
Installation site requirements: free from fire, explosion hazards, and chemical corrosive gases, ensuring a well-ventilated environment.
Note: Should operational conditions exceed these specified norms, users are encouraged to consult with the company for tailored solutions.
Technical parameters
Note: Our company is equipped to deliver custom solutions tailored to meet user-specific demands.
Model |
Voltage |
Current |
Rated maximum
breaking current |
1min power frequency dry withstand
voltage |
1min power frequency wet withstand
voltage |
Rated lightning impulse withstand
voltage |
Opening and closing
load current |
XS-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
XS-15/100(200) |
15 |
||||||
PD-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
PD-15/100(200) |
15 |
||||||
(H)RW3-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW3-12/100(200) |
12 |
||||||
(H)RW4-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW4-12/100(200) |
12 |
||||||
(H)RW7-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW7-12/100(200) |
12 |
||||||
(H)RW10-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW10-12/100(200) |
12 |
||||||
(H)RW10-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)RW10-12F/100(200) |
12 |
||||||
(H)RW11-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
! |
(H)RW11-12/100(200) |
12 |
||||||
(H)RW11-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)RW11-12F/100(200) |
12 |
||||||
(H)RW12-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
45 |
30 |
105 |
/ |
(H)RW12-12/100(200) |
12 |
||||||
(H)RW12-15/100(200) |
15 |
||||||
(H)PRWG1-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)PRWG1-12F/100(200) |
12 |
||||||
(H)RW33-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW33-15/100(200) |
15 |
||||||
(H)RW5-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |
|||||||
(H)RW10-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |
|||||||
(H)PRWG2-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |