Customization: | Available |
---|---|
Breaking Capacity: | 12kv/24kv/40.5kv |
Type: | Current Fuse |
Still deciding? Get samples of US$ 30/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
(H) RW(F) series outdoor high voltage AC drop fuse, ingeniously crafted for modern electrical systems, stands as the pinnacle of protection for outdoor overhead distribution networks operating at a frequency of 50Hz. With an impressive voltage range of 10kV (12/15/35/40.5), this fuse becomes an indispensable ally in shielding circuits and electrical equipment from potential overloads or short circuits within power systems. In normal operations, it remains securely tensioned and locked in the power line, ensuring seamless connectivity and reliability. When a fault arises, its responsive design swiftly allows the fault current to trigger the fuse, activating the release of the movable joint. This rapid mechanism causes the fuse tube to descend efficiently, severing the circuit with precision and providing critical safety protection during maintenance. Enhanced with an elastic contact and arc extinguishing cover, this load type fuse excels in efficiently managing and controlling the load current within the power system, ensuring optimal functionality and safety.
Our fuse is meticulously crafted to meet stringent technical standards, including GB / T 15166.3 - 2008 for high voltage AC fuses, Part 3: injection fuses, and DL / T 640 - 1997 for outdoor AC high voltage drop tested fuses. These standards assure top-tier performance and unmatched reliability under specified technical conditions, ensuring peace of mind and confidence in every use.
Working Environment:
This remarkable product is engineered to function flawlessly across a broad ambient temperature range from a frosty -40°C to a balmy +40°C, ensuring robust performance in a multitude of climates and weather conditions.
Engineered to tolerate a relative humidity where the daily average does not exceed 95% and the monthly average stays below 90%, this fuse is adept at withstanding even the most challenging high humidity environments.
It is ideally suited for altitudes not surpassing 3000 meters, making it versatile and adaptable to various geographical locations and terrains.
Designed to withstand outdoor wind velocities up to 34 meters per second, this fuse maintains steadfast stability and functionality even in the windiest of conditions, ensuring uncompromised performance.
The installation site must remain devoid of fire, explosion hazards, and chemical corrosive gases, while maintaining excellent ventilation to ensure optimal performance and safety standards.
Note: Should the prescribed normal use conditions be exceeded, we warmly invite users to engage with our company to explore potential solutions, ensuring continued safety, efficiency, and satisfaction.
Technical parameters
Note: We proudly offer customizable solutions, tailoring our products to meet the distinct needs and specifications of our valued users.
Model |
Voltage |
Current |
Rated maximum
breaking current |
1min power frequency dry withstand
voltage |
1min power frequency wet withstand
voltage |
Rated lightning impulse withstand
voltage |
Opening and closing
load current |
XS-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
XS-15/100(200) |
15 |
||||||
PD-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
PD-15/100(200) |
15 |
||||||
(H)RW3-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW3-12/100(200) |
12 |
||||||
(H)RW4-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW4-12/100(200) |
12 |
||||||
(H)RW7-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW7-12/100(200) |
12 |
||||||
(H)RW10-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW10-12/100(200) |
12 |
||||||
(H)RW10-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)RW10-12F/100(200) |
12 |
||||||
(H)RW11-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
! |
(H)RW11-12/100(200) |
12 |
||||||
(H)RW11-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)RW11-12F/100(200) |
12 |
||||||
(H)RW12-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
45 |
30 |
105 |
/ |
(H)RW12-12/100(200) |
12 |
||||||
(H)RW12-15/100(200) |
15 |
||||||
(H)PRWG1-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)PRWG1-12F/100(200) |
12 |
||||||
(H)RW33-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW33-15/100(200) |
15 |
||||||
(H)RW5-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |
|||||||
(H)RW10-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |
|||||||
(H)PRWG2-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |