Innovative Surge Arrester Solutions with Customizable Voltage and Protection

Product Details
Customization: Available
Type: Power Source Arrester
Structure: Zinc Oxide Arrester
Still deciding? Get samples of US$ 35/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

OEM Services
The supplier provides OEM services for popular brands
Quality Assurance
The supplier provides quality assurance
Private Mold
The supplier has private mold
Product Certification
The supplier's products already have relevant certification qualifications, including:
CE
to see all verified strength labels (20)
  • Innovative Surge Arrester Solutions with Customizable Voltage and Protection
  • Innovative Surge Arrester Solutions with Customizable Voltage and Protection
  • Innovative Surge Arrester Solutions with Customizable Voltage and Protection
  • Innovative Surge Arrester Solutions with Customizable Voltage and Protection
  • Innovative Surge Arrester Solutions with Customizable Voltage and Protection
  • Innovative Surge Arrester Solutions with Customizable Voltage and Protection
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Certifications
  • Company Profile
Overview

Basic Info.

Model NO.
YH series
Installation
According to Customer Requirements
Application
AC/DC System/Power Plants/Substation
Size
According to Customer Requirements
Operation Voltage
3 - 36kv
Shape
According to Customer Requirements
Material
ZnO
Certification
ROHS, ISO9001, CCC
Brand
Chbeb
Customizable
OEM/According to Customer Requirements
Voltage Customizable
30kv 33kv 36kv
Transport Package
Pallet
Trademark
CHBEB
Origin
China
HS Code
8535400000
Production Capacity
50000 Pieces/Quarter

Product Description

Product Description

Unveiling the Zinc Oxide Arrester from Beierbian Group Co., Ltd - a groundbreaking marvel in lightning protection for 10kV power distribution systems. This fully sealed, extraordinarily reliable device is a testament to advanced engineering, featuring a zinc oxide valve column expertly integrated with upper and lower electrodes. Enveloped in high-quality silicone rubber, it proudly offers unmatched features:

  1. This cutting-edge design skillfully conquers the sealing challenges historically faced by arresters. By harmoniously merging the core and jacket into one cohesive unit, it eliminates any potential cavities that could cause internal breathing issues. This innovative approach brilliantly circumvents the technical difficulties associated with moisture ingress in internal components, setting a new standard in arrester design.
  2. Equipped with a robust core designed to withstand substantial internal overvoltage, this arrester exemplifies superior aging resistance. It ensures consistent performance and steadfast protection, promising durability and reliability that endure through the years, safeguarding your systems like never before.

Through the integration of a specially designed valve plate and optimized core parameters, this device ensures that the core is resilient against challenges like arc grounding, PT resonance, and a wide range of operational overvoltages. It operates with unparalleled dependability under line voltage, enduring 2.5 to 3 times power frequency overvoltage. Its voltage withstand duration exceeds international standards by 1 to 3 orders of magnitude, offering unrivaled safety and operational longevity.
Innovative Surge Arrester Solutions with Customizable Voltage and Protection

Detailed Photos

Innovative Surge Arrester Solutions with Customizable Voltage and Protection

Innovative Surge Arrester Solutions with Customizable Voltage and Protection
Innovative Surge Arrester Solutions with Customizable Voltage and Protection
Innovative Surge Arrester Solutions with Customizable Voltage and Protection
Innovative Surge Arrester Solutions with Customizable Voltage and Protection
Innovative Surge Arrester Solutions with Customizable Voltage and Protection
Innovative Surge Arrester Solutions with Customizable Voltage and Protection

Product Parameters

Main Characteristics of Jacket Materials and Product Usage Environment:

Item

Unit

Norm

Shore Hardness A

/

60

Tensile Strength

mpa

≥35

Breaking Elongation

%

≥250

Oxygen Index

/

45

Resistivity

Ω.m

≥1×1013

Breakdown Strength

MV/m

≥25

Tracking

kV

4.5

Durability

Not less than 20 years

Working Environment:

Expertly crafted to ensure flawless performance in both indoor and outdoor settings;

Operates effectively at altitudes soaring up to an impressive 3000 meters;

Built to withstand a wide range of temperatures from a brisk -40°C to a warm +60°C;

Adept at handling power supply frequencies that vary from a stable 48Hz to a lively 62Hz;

Maintains power frequency voltage between terminals within ideal limits for extended use, ensuring longevity;

Designed to endure seismic activities with intensity levels not exceeding 8 degrees.

Engineered to withstand outdoor wind velocities reaching up to 35 meters per second;

Note:

Should circumstances arise where conditions extend beyond typical operational limits, engage with our team for customized solutions.

Main Technical Parameters

Model

Nominal Voltage

(rms)

Rated Voltage OArrester

(rms)

Continuous Operating Voltage

(rms)

DC 1mA reference voltage
kV not less than

The residual voltage under nominal discharge current
kV (Crest) not greater than

Steep wave impact residual voltage
kV (Crest) not greater than

2ms square wave flow capacity
A

Operation Place

YH5WS-3.8/17

3

3.8

2.0

7.5

17.0

19.6

100

 

Distribution Type

YH5WS-5/15

3

5

4.0

7.5

15.0

17.3

150

YH5WS-7.6/30

6

7.6

4.0

15.0

15.0

34.5

100

YH5WS-10/30

6

10

8.0

15.0

30.0

34.6

150

YH5WS-12.7/50

10

12.7

10

26.0

50.0

57.5

100

YH5WS-16.5/50

10

16.5

12.7

26.0

50.0

57.5

100

YH5WS-17/50

10

17

13.6

26.0

50.0

57.5

150

YH5WS-17/45

10

17

13.6

25.0

45.0

/

250

YH10WS-17/45

10

17

13.6

25.0

45.0

/

400

YH5WZ-5/13.5

3

5

4.0

7.2

13.5

15.5

200

Power Station Type

YH5WZ-7.6/27

6

7.6

4.0

14.4

27.0

31.0

150

YH5WZ-10/27

6

10

8.0

14.4

27.0

31.0

200

YH5WZ-42/134

35

42

23.4

73

134

154

150

YH5WZ-12.7/45

10

12.7

6.6

24.0

45.0

51.8

150

YH5WZ-16.5/45

10

16.5

13.2

24.0

45.0

51.8

150

YH5WZ-17/45

10

17

13.6

24.0

45.0

51.8

200

YH5WZ-51/134

35

51

40.8

73.0

134

154

400

YH10WZ-17/45

10

17

13.6

24.0

45.0

51.8

200

YH10WZ-51/134

35

51

40.8

73.0

134

154

400

YH5WR-5/13.5

3

5

4.0

7.2

13.5

/

400

Capacitive Type

YH5WR-7.6/27

6

7.6

4.0

13.8

27.0

/

400

YH5WR-10/27

6

10

8.0

14.4

27.0

/

400

YH5WR-12.7/45

10

12.7

6.6

23.0

45.0

/

400

YH5WR 17/45

10

17

13.6

24.0

45.0

/

400

YH5WX-51/134

35

51

40.8

73

134.0

154

400

Line type

YH1.5W-30/80

35

30

24

44

80.0

/

600

Neutral Type

Note: Constructed with a durable Polymeric build for enhanced resilience

Model

Nominal Voltage

(rms)

Rated Voltage OArrester

(rms)

Continuous Operating Voltage

(rms)

DC 1mA Reference Voltage
kV Not Less Than

The Residual Voltage Under Nominal Discharge Current
kV (Crest)
Not Greater Than

Steep Wave Impact Residual Voltage
kV (Crest)
Not Greater Than

2ms Square Wave Flow Capacity
A

Operation Place

Y5WS-5/15

3

5

4.0

7.5

15.0

17.3

150

Distribution Type

Y5WS-7.6/30

6

7.6

4.0

15.0

15.0

34.5

100

Y5WS-10/30

6

10

8.0

15.0

30.0

34.6

150

Y5WS-12.7/50

10

12.7

10

26.0

50.0

57.5

100

Y5WS-16.5/50

10

16.5

12.7

26.0

50.0

57.5

100

Y5WS-17/50

10

17

13.6

26.0

50.0

57.5

150

Y5WZ-5/13.5

3

5

4.0

7.2

13.5

15.5

200

Power Station Type

Y5WZ-7.6/27

6

7.6

4.0

14.4

27.0

31.0

150

Y5WZ-10/27

6

10

8.0

14.4

27.0

31.0

200

Y5WZ-42/134

35

42

23.4

73

134

154

150

Y5WZ-12.7/45

10

12.7

6.6

24.0

45.0

51.8

150

Y5WZ-16.5/45

10

16.5

13.2

24.0

45.0

51.8

150

Y5WZ-17/45

10

17

13.6

24.0

45.0

51.8

200

Y5WZ-51/134

35

51

40.8

73.0

134

154

400

Y5WR-5/13.5

3

5

4.0

7.2

13.5

/

400

Capacitive Type

Y5WR-7.6/27

6

7.6

4.0

13.8

27.0

/

400

Y5WR-10/27

6

10

8.0

14.4

27.0

/

400

Y5WR-12.7/45

10

12.7

6.6

23.0

45.0

/

400

Y5WR-17/45

10

17

13.6

24.0

45.0

/

400

Y1.5W-0.28/1.3

0.22

0.28

0.24

0.6

1.3

/

75

Low Voltage

Y1.5W-0.5/2.6

0.38

0.5

0.24

1.2

2.6

/

75

Note:Porcelain

Model

 

Nominal Voltage
(Valid values)

 

Rated Voltage Of Arrester
(Valid values)

 

The Wave Front

Steepness Of The Shock Discharge

 

DC 1mA Reference Voltage

kV Not Less Than

 

1.2/50 Impulse Discharge Voltage

Not Greater Than

 

Wavefront Impulse

Discharge Voltage

 

kV Not Greater Than

The Residual Voltage Under Nominal Discharge

Current 8/20μs

 

kV Not Greater Than

 

2000μs Square

Wave Flow Capacity

 

4/10μs Impulse

Current Capacity

Y5CS-7.6/27

6

7.6

63

16

35

43.8

27

75

25

Y5CZ-7.6/24

6

7.6

63

16

30

37.5

24

150

40

Y5CS-12.7/45

10

12.7

106

26

50

62.5

45

75

25

Y5CS-12.7/41

10

12.7

106

26

45

56.5

41

200

40

Y5CZ-42/124

35

42.0

343

82

134

168

124

200

40

Note: Features a Porcelain Series Gap specification for additional reliability

Installation

(1) Before installation, confirm that the arrester's nameplate matches the system's rated voltage at the site of installation, ensuring compatibility;

(2) Provides versatility with options for suspension or vertical installations. For vertical setups, it is crucial to avoid using the arrester as a load-bearing insulator;

(3) Optimize the length of the lead wire to maintain protection efficiency and prevent unnecessary stress on equipment.

Test

  • lTo enhance operational reliability, conduct preventive tests every 4-5 years. Focus primarily on measuring U1mA at both DC 1mA arrester terminals.
  • lPrior to installation, confirm that the U1mA voltage is at least 97% of the original factory output and ensure proper documentation of this data.
  • lDuring preventive maintenance, verify that the U1mA voltage does not dip below 26kV, securing ongoing performance.
  • lNote: Minimize harmonic components in the DC power supply during tests to avoid inaccurate U1mA readings due to waveform distortion.
  • lThe newly launched 10kV synthetic insulated zinc oxide arrester for power distribution has triumphantly passed comprehensive laboratory testing, proving its functionality under outdoor line voltage for an impressive 15 months. The results affirmed the jacket's superior quality, the arrester's structural reliability, and core robustness. With performance data from 2,000 units annually, this product guarantees exceptional protection, reduced failure rates, and maintenance-free operation throughout its lifecycle.Innovative Surge Arrester Solutions with Customizable Voltage and Protection
Certifications

Innovative Surge Arrester Solutions with Customizable Voltage and Protection

Company Profile

Innovative Surge Arrester Solutions with Customizable Voltage and Protection

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier