Customization: | Available |
---|---|
Breaking Capacity: | 12kv/24kv/40.5kv |
Type: | Current Fuse |
Still deciding? Get samples of US$ 30/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
(H) RW(F) Series Outdoor High Voltage AC Drop Fuse - a cutting-edge solution crafted for optimal performance in overhead distribution systems. Designed to operate seamlessly at a rated frequency of 50Hz and voltage levels of 10kV (12/15/35/40.5), this fuse is an indispensable protective element for circuits and electrical equipment. It safeguards against power system overloads or short circuits with precision. Under normal conditions, the fuse remains in a tensile state, securely locked in the power line. In the event of a line fault, the fault current activates the fuse, releasing the movable joint, causing the fuse tube to swiftly detach, thereby interrupting the circuit and ensuring superior safety protection. Enhanced with elastic contact and an arc extinguishing cover, this load type fuse surpasses ordinary fuses by efficiently managing the load current within the power system.
Our fuses are manufactured in accordance with stringent technical standards, including GB / T 15166.3 - 2008 for high voltage AC fuses, Part 3: injection fuses, alongside DL / T 640 - 1997 standards for outdoor AC high voltage drop-tested fuses and fuse links, ensuring unparalleled reliability and quality.
Working Environment:
Ambient temperature: engineered to operate flawlessly from -40°C to +40°C;
Relative humidity: designed to withstand a daily average of up to 95%, and a monthly average not exceeding 90%;
Adaptable for altitudes reaching up to 3000 meters;
Capable of enduring outdoor wind speeds up to 34 meters/second;
Installation site specifications: Requires a location free from fire, explosion hazards, and chemically corrosive gases, ensuring a well-ventilated environment.
Note: Should your operational conditions exceed these parameters, customization is available through negotiation with our company.
Technical parameters
Note: Our company is committed to accommodating user-specific requirements, providing tailored solutions to meet diverse needs.
Model |
Voltage |
Current |
Rated maximum
breaking current |
1min power frequency dry withstand
voltage |
1min power frequency wet withstand
voltage |
Rated lightning impulse withstand
voltage |
Opening and closing
load current |
XS-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
XS-15/100(200) |
15 |
||||||
PD-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
PD-15/100(200) |
15 |
||||||
(H)RW3-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW3-12/100(200) |
12 |
||||||
(H)RW4-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW4-12/100(200) |
12 |
||||||
(H)RW7-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW7-12/100(200) |
12 |
||||||
(H)RW10-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW10-12/100(200) |
12 |
||||||
(H)RW10-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)RW10-12F/100(200) |
12 |
||||||
(H)RW11-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
! |
(H)RW11-12/100(200) |
12 |
||||||
(H)RW11-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)RW11-12F/100(200) |
12 |
||||||
(H)RW12-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
45 |
30 |
105 |
/ |
(H)RW12-12/100(200) |
12 |
||||||
(H)RW12-15/100(200) |
15 |
||||||
(H)PRWG1-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)PRWG1-12F/100(200) |
12 |
||||||
(H)RW33-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW33-15/100(200) |
15 |
||||||
(H)RW5-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |
|||||||
(H)RW10-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |
|||||||
(H)PRWG2-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |