Customization: | Available |
---|---|
Breaking Capacity: | 12kv/24kv/40.5kv |
Type: | Current Fuse |
Still deciding? Get samples of US$ 30/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Discover the power and precision of the (H) RW(F) series outdoor high voltage AC drop fuse, affectionately known as the 'fuse'. Specially crafted for outdoor overhead distribution systems, it boasts a rated frequency of 50Hz and a rated voltage spectrum of 10kV (12/15/35/40.5). This innovative protective device acts as a safeguard for circuits and electrical equipment, stepping in during overloads or short-circuit faults within power systems. Under normal conditions, the fuse remains securely in place, locked and tensioned in series within the power line. However, when a fault arises, the fault current engages the fuse, prompting it to blow and liberate the movable joint. This swift action causes the fuse tube to drop instantly, effectively cutting off the circuit and ensuring optimal safety for line and equipment maintenance. Enhancing the ordinary design, our load type fuse features an elastic contact and arc extinguishing cover, allowing it to efficiently open and close the load current within the power system.
Our fuse adheres to rigorous technical standards, including GB / T 15166.3 - 2008 for high voltage AC fuses - Part 3: injection fuses, as well as DL / T 640 - 1997 for outdoor AC high voltage drop-tested fuses and fuse links ordering technical conditions.
Working Environment:
Capable of withstanding extreme ambient temperatures ranging from -40°C to +40°C;
Designed for environments where relative humidity averages do not exceed 95% daily and 90% monthly;
Perfect for installations at altitudes up to 3000 meters;
Built to endure outdoor wind speeds of up to 34 meters per second;
Ideal for installation in locations free from fire hazards, explosion risks, and corrosive chemical gases, ensuring well-ventilated surroundings.
Note: Should your conditions surpass these specifications, we invite you to negotiate with the company for tailored solutions.
Technical parameters
Note: Our company is committed to providing products aligned with specific user requirements.
Model |
Voltage |
Current |
Rated maximum
breaking current |
1min power frequency dry withstand
voltage |
1min power frequency wet withstand
voltage |
Rated lightning impulse withstand
voltage |
Opening and closing
load current |
XS-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
XS-15/100(200) |
15 |
||||||
PD-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
PD-15/100(200) |
15 |
||||||
(H)RW3-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW3-12/100(200) |
12 |
||||||
(H)RW4-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW4-12/100(200) |
12 |
||||||
(H)RW7-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW7-12/100(200) |
12 |
||||||
(H)RW10-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW10-12/100(200) |
12 |
||||||
(H)RW10-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)RW10-12F/100(200) |
12 |
||||||
(H)RW11-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
! |
(H)RW11-12/100(200) |
12 |
||||||
(H)RW11-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)RW11-12F/100(200) |
12 |
||||||
(H)RW12-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
45 |
30 |
105 |
/ |
(H)RW12-12/100(200) |
12 |
||||||
(H)RW12-15/100(200) |
15 |
||||||
(H)PRWG1-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)PRWG1-12F/100(200) |
12 |
||||||
(H)RW33-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW33-15/100(200) |
15 |
||||||
(H)RW5-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |
|||||||
(H)RW10-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |
|||||||
(H)PRWG2-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |