Customization: | Available |
---|---|
Breaking Capacity: | 12kv/24kv/40.5kv |
Type: | Current Fuse |
Still deciding? Get samples of US$ 30/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
(H) RW(F) series outdoor high voltage AC drop fuse is a hallmark of exceptional engineering for contemporary electrical infrastructures. Specially crafted for outdoor overhead distribution networks operating efficiently at a frequency of 50Hz, it upholds a remarkable voltage range of 10kV (12/15/35/40.5). This indispensable fuse acts as a vigilant guardian, safeguarding circuits and electrical apparatus against potential overloads or short-circuit anomalies in power systems. Under regular conditions, it remains tensioned and securely locked within the power line, ensuring flawless connectivity. In the event of a fault, its adept design allows the fault current to blow the fuse, thereby triggering the release of the movable joint. This rapid action causes the fuse tube to drop swiftly, ensuring the circuit is effectively interrupted, offering paramount safety protection during maintenance operations. Enhanced with an elastic contact and innovative arc extinguishing cover, this load type fuse is adept at efficiently opening and closing the load current within power systems.
Our fuse is intricately designed to meet stringent technical standards, including GB / T 15166.3 - 2008 for high voltage AC fuses, Part 3: injection fuses, and DL / T 640 - 1997 for rigorously tested outdoor AC high voltage drop fuses. These standards ensure unparalleled performance and reliability consistent with specified technical guidelines.
Working Environment:
This product is engineered to thrive in a wide ambient temperature spectrum ranging from a frigid -40°C to a balmy +40°C, guaranteeing resilient performance across diverse climates.
With a commendable relative humidity adaptability, where the daily average does not exceed 95% and the monthly average is maintained below 90%, this fuse is constructed to withstand high humidity environments, ensuring unwavering efficiency.
The fuse is designed to perform impeccably at altitudes not exceeding 3000 meters, making it suitable for a variety of geographical landscapes.
Crafted to resist outdoor wind velocities up to 34 meters per second, this fuse exhibits unmatched stability and functionality, even in gusty conditions.
The installation site must be devoid of fire, explosion hazards, and chemically corrosive gases, while ensuring proper ventilation for optimal performance and safety assurance.
Note: If the prescribed normal usage conditions are surpassed, we encourage users to engage with our company to explore potential solutions that ensure continued safety and operational efficiency.
Technical parameters
Note: We provide customizable solutions, tailoring products to meet the unique specifications and requirements of our users, ensuring a perfect fit for every need.
Model |
Voltage |
Current |
Rated maximum
breaking current |
1min power frequency dry withstand
voltage |
1min power frequency wet withstand
voltage |
Rated lightning impulse withstand
voltage |
Opening and closing
load current |
XS-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
XS-15/100(200) |
15 |
||||||
PD-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
PD-15/100(200) |
15 |
||||||
(H)RW3-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW3-12/100(200) |
12 |
||||||
(H)RW4-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW4-12/100(200) |
12 |
||||||
(H)RW7-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW7-12/100(200) |
12 |
||||||
(H)RW10-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW10-12/100(200) |
12 |
||||||
(H)RW10-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)RW10-12F/100(200) |
12 |
||||||
(H)RW11-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
! |
(H)RW11-12/100(200) |
12 |
||||||
(H)RW11-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)RW11-12F/100(200) |
12 |
||||||
(H)RW12-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
45 |
30 |
105 |
/ |
(H)RW12-12/100(200) |
12 |
||||||
(H)RW12-15/100(200) |
15 |
||||||
(H)PRWG1-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)PRWG1-12F/100(200) |
12 |
||||||
(H)RW33-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW33-15/100(200) |
15 |
||||||
(H)RW5-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |
|||||||
(H)RW10-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |
|||||||
(H)PRWG2-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |