Customization: | Available |
---|---|
Breaking Capacity: | 12kv/24kv/40.5kv |
Type: | Current Fuse |
Still deciding? Get samples of US$ 30/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
(H) RW(F) series outdoor high voltage AC drop fuse, hereinafter referred to as the "fuse," is expertly crafted for use in outdoor overhead distribution systems with a rated frequency of 50Hz and voltage options of 10kV (12/15/35/40.5). This fuse serves as a crucial protective component in safeguarding circuits and electrical equipment from potential overloads or short circuit faults within power systems. During standard operations, the fuse is seamlessly integrated in series within the power line, remaining in a carefully tensioned state with a secure lock on its movable joint. Upon detection of a line fault, the fault current effectively triggers the fuse to blow, instantly releasing the movable joint and swiftly dropping the fuse tube to disconnect the circuit. This essential safety mechanism ensures efficient protection for both line and equipment maintenance. Enhanced with elastic contacts and an advanced arc extinguishing cover, the load-type fuse is adept at opening and closing load currents within the power system.
The fuse adheres to stringent technical standards including GB / T 15166.3 - 2008 high voltage AC fuses - Part 3: injection fuses, as well as DL / T 640 - 1997 outdoor AC high voltage drop tested fuses and fuse links ordering technical conditions, assuring compliance and reliability.
Working Environment:
Ambient temperature: Ranges from a crisp -40°C to a warm +40°C;
Relative humidity: Daily average does not exceed 95%, with a monthly average not surpassing 90%;
Altitude: The installation location is ideally positioned at elevations not exceeding 3000 meters;
Outdoor wind speed: Stays within a robust 34 meters/second limit;
Installation site: Must be free from fire hazards, explosion risks, and exposure to chemical corrosive gases, ensuring a well-ventilated environment.
Note: Should your operational conditions exceed the aforementioned standard use parameters, we invite users to engage in a collaborative discussion with our company for tailored solutions.
Technical parameters
Note: Our company readily accommodates special requests, offering product configurations tailored to user-specific requirements.
Model |
Voltage |
Current |
Rated maximum
breaking current |
1min power frequency dry withstand
voltage |
1min power frequency wet withstand
voltage |
Rated lightning impulse withstand
voltage |
Opening and closing
load current |
XS-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
XS-15/100(200) |
15 |
||||||
PD-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
PD-15/100(200) |
15 |
||||||
(H)RW3-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW3-12/100(200) |
12 |
||||||
(H)RW4-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW4-12/100(200) |
12 |
||||||
(H)RW7-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW7-12/100(200) |
12 |
||||||
(H)RW10-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW10-12/100(200) |
12 |
||||||
(H)RW10-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)RW10-12F/100(200) |
12 |
||||||
(H)RW11-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
! |
(H)RW11-12/100(200) |
12 |
||||||
(H)RW11-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)RW11-12F/100(200) |
12 |
||||||
(H)RW12-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
45 |
30 |
105 |
/ |
(H)RW12-12/100(200) |
12 |
||||||
(H)RW12-15/100(200) |
15 |
||||||
(H)PRWG1-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)PRWG1-12F/100(200) |
12 |
||||||
(H)RW33-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW33-15/100(200) |
15 |
||||||
(H)RW5-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |
|||||||
(H)RW10-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |
|||||||
(H)PRWG2-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |