Outdoor AC Disconnector with High Voltage Load Break Isolation Capabilities

Product Details
Customization: Available
Type: 10kv/12kv/15kv
Structure: According to Customer Requirements
Still deciding? Get samples of US$ 140/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

OEM Services
The supplier provides OEM services for popular brands
Quality Assurance
The supplier provides quality assurance
Private Mold
The supplier has private mold
Product Certification
The supplier's products already have relevant certification qualifications, including:
CE
to see all verified strength labels (20)
  • Outdoor AC Disconnector with High Voltage Load Break Isolation Capabilities
  • Outdoor AC Disconnector with High Voltage Load Break Isolation Capabilities
  • Outdoor AC Disconnector with High Voltage Load Break Isolation Capabilities
  • Outdoor AC Disconnector with High Voltage Load Break Isolation Capabilities
  • Outdoor AC Disconnector with High Voltage Load Break Isolation Capabilities
  • Outdoor AC Disconnector with High Voltage Load Break Isolation Capabilities
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Certifications
Overview

Basic Info.

Model NO.
(H)GWBEB
Installation
Outdoor High-voltage
Operation
Manual/Electric/Pneumatic/Hydraulic
Grounding Mode
According to Customer Requirements
Movement Mode
According to Customer Requirements
Number of Poles
According to Customer Requirements
Grounding
According to Customer Requirements
Series
Two
Run
According to Customer Requirements
Switching Mode
According to Customer Requirements
Common Model
Gw9
Structure of Operating
According to Customer Requirements
Certification
ISO, RoHS, CE
Brand
Chbeb
Customizable
OEM/According to Customer Requirements
Transport Package
Standard Shipping Packing
Specification
45*55*38mm
Trademark
CHBEB
Origin
China
HS Code
853530900
Production Capacity
5000 PCS/Quarter

Product Description

Outdoor AC Disconnector with High Voltage Load Break Isolation Capabilities
Product Description

Introducing the (H)GWBEB type Outdoor High-Voltage Isolation Switch, also known as the Isolation Disconnect Switch. This cutting-edge technology is crafted for superior performance on 10(12, 15, 24)kV high voltage power transmission and distribution lines. Expertly engineered to open and close single-phase or three-phase circuits, this switch operates seamlessly with voltage present, yet without load, ensuring maximum safety and reliability.

Ideal for single-phase applications in three-phase systems, this switch boasts a simple, cost-effective, and user-friendly design. With rated currents of 200, 400, 600, 800, 1000, and 1250 amps, it offers versatility and adaptability. The construction features a robust base, durable post insulators, conductive components, and a precision-engineered mechanical section. Utilizing a sophisticated gate knife structure, the switch deftly manages circuit operations. Each phase's gate knife includes two conductive blades, enhanced with external compression springs for optimal performance. The spring height is adjustable to ensure the required contact pressure. Operated with an insulated hook stick, the switch also includes a state-of-the-art self-locking device for secure handling.

Working Environment:

Optimally designed for altitudes below 1000 meters,

Crafted to perform in ambient temperatures from a chilly -30°C up to a warm +40°C.

Engineered to withstand outdoor wind speeds up to 35 meters/second,

Resilient against seismic intensities up to 8 degrees, ensuring stability in areas without excessive vibrations.

Installation sites must be free from harmful gases, chemical deposits, salt mist, dust, dirt, or other corrosive or explosive elements that could adversely affect insulation and conductivity.

Note:

IF THE CONDITIONS FOR NORMAL USE EXCEED THE SPECIFIED LIMITS, WE WELCOME USERS TO CONSULT WITH THE COMPANY FOR CUSTOM SOLUTIONS.

 

Installation, Use and Adjustment

Pre-installation work

  1. Thoroughly remove dust and dirt from all components, ensuring the insulating porcelain bottle surfaces are meticulously clean.
  2. Carefully scrub the wiring area of the ground screw to ensure pristine connectivity.
  3. Generously apply a coat of industrial Vaseline to all rotating parts and contact zones for smooth operation.
  4. Inspect the contact surfaces and adjust the compression spring height to conform precisely with Table II specifications, ensuring adequate contact pressure.
  5. This switch is exclusively designed for hoisting applications, intended for use in tandem with transformers along the line.
  6. Designed for versatility, the switch with rated currents of 200-400 ampere hours typically utilizes three mounting holes, while those rated 600-1000A also employ three mounting holes.

An annual inspection protocol should include the following checks:
Remove any accumulated dirt from conductive parts, contact surfaces, and insulating porcelain bottle surfaces to maintain peak performance.

Conduct a thorough inspection of all components, paying special attention to the integrity of the insulating porcelain bottle for any signs of damage or cracks.

Ensure that the conductive part's contact surface remains impeccable and optimal for superior functionality.


Outdoor AC Disconnector with High Voltage Load Break Isolation Capabilities

Detailed Photos

 

Outdoor AC Disconnector with High Voltage Load Break Isolation Capabilities
Outdoor AC Disconnector with High Voltage Load Break Isolation Capabilities
Outdoor AC Disconnector with High Voltage Load Break Isolation Capabilities
Outdoor AC Disconnector with High Voltage Load Break Isolation Capabilities


Outdoor AC Disconnector with High Voltage Load Break Isolation Capabilities
Outdoor AC Disconnector with High Voltage Load Break Isolation Capabilities

Outdoor AC Disconnector with High Voltage Load Break Isolation Capabilities
Outdoor AC Disconnector with High Voltage Load Break Isolation Capabilities
Outdoor AC Disconnector with High Voltage Load Break Isolation Capabilities
Outdoor AC Disconnector with High Voltage Load Break Isolation Capabilities
Outdoor AC Disconnector with High Voltage Load Break Isolation Capabilities
Outdoor AC Disconnector with High Voltage Load Break Isolation Capabilities
Outdoor AC Disconnector with High Voltage Load Break Isolation Capabilities
Outdoor AC Disconnector with High Voltage Load Break Isolation Capabilities
Outdoor AC Disconnector with High Voltage Load Break Isolation Capabilities
Outdoor AC Disconnector with High Voltage Load Break Isolation Capabilities
Outdoor AC Disconnector with High Voltage Load Break Isolation Capabilities
Outdoor AC Disconnector with High Voltage Load Break Isolation Capabilities

 

Product Parameters

The main technical parameters

Table I

Model

Rated voltage
kV

 

Rated current
A

kA

 

10 seconds thermal stable current
kA

peak

Valid values

 

(H)GW

 

10

12

15

200

5

9

5

400

21

15

10

600

35

25

14

630

35

25

14

800

35

25

14

1000

50

35

20

Contact force parameters

Table II

Model

Rated current(A)

contact pressure(kgf)

(H)GW

5

9

21

15

35

25

35

25

35

25

50

35

Certifications

Outdoor AC Disconnector with High Voltage Load Break Isolation CapabilitiesOutdoor AC Disconnector with High Voltage Load Break Isolation Capabilities

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier