(H) RW(F) series outdoor high voltage AC drop fuse (hereinafter referred to as "fuse") is precisely engineered for outdoor overhead distribution systems with a rated frequency of 50Hz and rated voltage options ranging from 10kV to 40.5kV. This innovative fuse serves as an essential protective element for circuits or electrical equipment, guarding against overloads or short circuit faults in power systems. Under normal conditions, the fuse is integrated in series within the power line, maintaining a tensioned state with securely locked movable joints. In the event of a line failure, the fault current activates the fuse, triggering a swift release of the movable joint, resulting in the rapid drop of the fuse tube and immediate circuit disconnection. This key functionality ensures vital safety protection during line and equipment maintenance. Enhanced with elastic contact and an advanced arc extinguishing cover, this load type fuse offers superior performance in opening and closing load currents within the power system compared to ordinary types.
The fuse adheres to rigorous technical standards including GB / T 15166.3 - 2008 for high voltage AC fuses - Part 3: injection fuses, as well as DL / T 640 - 1997 for outdoor AC high voltage drop tested fuses and fuse links ordering technical conditions, ensuring reliable and standardized quality.
Working Environment:
Ambient temperature: Ranging from a brisk -40°C to a warm +40°C;
Relative humidity: Daily averages that do not exceed 95%, with monthly averages capped at 90%;
The altitude must not surpass an elevation of 3000 meters;
Outdoor wind velocities should remain below the threshold of 34 meters per second;
Installation site: Should be devoid of fire, explosion hazards, and chemical corrosive gases, while ensuring the area is well-ventilated.
Note: If operational conditions exceed the specified norms, users are encouraged to engage in consultations with our company for tailored solutions.
Technical parameters
Note: We are equipped to accommodate user-specific requirements, providing customized product solutions.
Model |
Voltage |
Current |
Rated maximum
breaking current |
1min power frequency dry withstand
voltage |
1min power frequency wet withstand
voltage |
Rated lightning impulse withstand
voltage |
Opening and closing
load current |
XS-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
XS-15/100(200) |
15 |
||||||
PD-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
PD-15/100(200) |
15 |
||||||
(H)RW3-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW3-12/100(200) |
12 |
||||||
(H)RW4-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW4-12/100(200) |
12 |
||||||
(H)RW7-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW7-12/100(200) |
12 |
||||||
(H)RW10-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW10-12/100(200) |
12 |
||||||
(H)RW10-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)RW10-12F/100(200) |
12 |
||||||
(H)RW11-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
! |
(H)RW11-12/100(200) |
12 |
||||||
(H)RW11-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)RW11-12F/100(200) |
12 |
||||||
(H)RW12-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
45 |
30 |
105 |
/ |
(H)RW12-12/100(200) |
12 |
||||||
(H)RW12-15/100(200) |
15 |
||||||
(H)PRWG1-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)PRWG1-12F/100(200) |
12 |
||||||
(H)RW33-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW33-15/100(200) |
15 |
||||||
(H)RW5-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |
|||||||
(H)RW10-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |
|||||||
(H)PRWG2-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |