Customization: | Available |
---|---|
Breaking Capacity: | 12kv/24kv/40.5kv |
Type: | Current Fuse |
Still deciding? Get samples of US$ 30/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
(H) RW(F) series outdoor high voltage AC drop fuse (hereinafter referred to as "fuse") is expertly engineered for outdoor overhead distribution systems, boasting a rated frequency of 50Hz and a rated voltage of 10kV (with options for 12/15/35/40.5). This remarkable device acts as a guardian for your circuits and electrical equipment, offering indispensable protection against overloads and short circuits in power systems. Seamlessly integrated into power lines, the fuse maintains a tensioned state with its locked movable joint. In the event of a system failure, the fault current triggers the fuse to blow, releasing the movable joint and swiftly dropping the fuse tube to disconnect and safeguard the circuit. This essential safety feature ensures the protection and maintenance of your lines and equipment. Enhanced with elastic contact and an advanced arc extinguishing cover, this load type fuse surpasses ordinary types, providing reliable operations for opening and closing load currents within power systems.
The fuse adheres to stringent technical standards, including GB / T 15166.3 - 2008 for high voltage AC fuses - Part 3: injection fuses, and DL / T 640 - 1997 for outdoor AC high voltage drop tested fuses and fuse links ordering technical conditions, ensuring exceptional reliability and performance.
Working Environment:
Ambient temperature: -40°C to +40°C; a wide operational range for diverse climatic conditions.
Relative humidity: maintains optimal performance with a daily average not exceeding 95% and a monthly average not exceeding 90%;
Altitude: Designed for locations where altitude does not exceed 3000 meters;
Wind resistance: Capable of withstanding outdoor wind speeds not exceeding 34 meters/second;
Installation site: Ideally suited for areas free from fire, explosion hazards, and chemical corrosive gases, ensuring a well-ventilated environment.
Note: Should your application exceed these normal conditions, users are encouraged to negotiate customized solutions with the company, enabling tailored adaptability.
Technical Parameters
Note: Our company stands ready to cater to specific user requirements with bespoke product offerings.
Model |
Voltage |
Current |
Rated maximum
breaking current |
1min power frequency dry withstand
voltage |
1min power frequency wet withstand
voltage |
Rated lightning impulse withstand
voltage |
Opening and closing
load current |
XS-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
XS-15/100(200) |
15 |
||||||
PD-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
PD-15/100(200) |
15 |
||||||
(H)RW3-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW3-12/100(200) |
12 |
||||||
(H)RW4-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW4-12/100(200) |
12 |
||||||
(H)RW7-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW7-12/100(200) |
12 |
||||||
(H)RW10-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW10-12/100(200) |
12 |
||||||
(H)RW10-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)RW10-12F/100(200) |
12 |
||||||
(H)RW11-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
! |
(H)RW11-12/100(200) |
12 |
||||||
(H)RW11-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)RW11-12F/100(200) |
12 |
||||||
(H)RW12-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
45 |
30 |
105 |
/ |
(H)RW12-12/100(200) |
12 |
||||||
(H)RW12-15/100(200) |
15 |
||||||
(H)PRWG1-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)PRWG1-12F/100(200) |
12 |
||||||
(H)RW33-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW33-15/100(200) |
15 |
||||||
(H)RW5-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |
|||||||
(H)RW10-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |
|||||||
(H)PRWG2-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |