Customization: | Available |
---|---|
Type: | High-voltage |
Structure: | Three-column Disconnector |
Still deciding? Get samples of US$ 800/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Introducing the ZW32-12 Outdoor High Voltage Vacuum Circuit Breaker, the epitome of excellence for cutting-edge outdoor distribution networks. Affectionately dubbed the 'circuit breaker,' this state-of-the-art switchgear is crafted for a 12kV rated voltage and a robust three-phase AC at 50Hz. This innovative circuit breaker adeptly manages the seamless interruption and reconnection of load current, overload current, and short circuit current within power grids. With advanced overload and short circuit protective capabilities, it meets control and measurement needs with finesse, offering sophisticated remote control and monitoring functions. Its expansive application realm includes substations, industrial sectors, and mining enterprise distribution systems, making it the premium choice for environments demanding frequent operations. Experience unrivaled control and efficiency with this essential asset for modern electrical infrastructures.
Structural Features:
Meticulously crafted with precision, the circuit breaker showcases a refined three-phase pillar dry design, embodying engineering excellence.
Expertly engineered with a fully enclosed structure, it offers outstanding sealing, exceptional moisture resistance, and anti-condensation attributes, perfectly suited for high-temperature and humid conditions.
Utilizing state-of-the-art vacuum arc extinguishing technology, it provides unparalleled insulation reliability, setting a new standard in performance.
Ensures impeccable opening and closing performance, prioritizing safety with no risk of combustion or explosion, offering peace of mind.
Designed to be compact and lightweight, this sophisticated device is maintenance-free, boasting an impressive lifespan that speaks for itself.
Features versatile operation capabilities, offering manual, electric, or remote control options for the ultimate convenience and adaptability.
The operating mechanism is meticulously sealed at the switch box's base, effectively safeguarding against the challenges of outdoor environmental corrosion.
Showcasing an innovative and streamlined design that includes a restless mechanism, it guarantees reliable dynamic performance, a compact structure, and an extraordinary service life reaching up to 10,000 cycles, ensuring long-lasting dependability.
Main Technical Parameters:
No |
Name |
Unit |
Data |
|||
1 |
Rated voltage |
kV |
12 |
|||
2 |
Rated current |
A |
630 |
1250 |
||
3 |
Rated frequency |
Hz |
50 |
|||
4 |
Rated insulation level |
1min power frequency withstand voltage |
Dry test |
/ |
42/48(fracture) |
|
Wet test |
34 |
|||||
Secondary circuit to ground |
2 |
|||||
Lightning impulse withstand voltage (peak value) |
75/85(fracture) |
|||||
5 |
Rated short circuit making current (peak value) |
kA |
50 |
63 |
||
6 |
Rated short time withstand current |
kA |
20 |
25 |
||
7 |
Rated peak withstand current |
kA |
50 |
63 |
||
8 |
Breaking times of rated short circuit breaking current |
Times |
30 |
|||
9 |
Rated short circuit duration |
s |
4 |
|||
10 |
Rated operating voltage and rated voltage of auxiliary circuit |
V |
DC220,AC220 ,AC/DC220 |
|||
11 |
Rated operation sequence |
/ |
Off-0.3s-on-off-180s-on-off |
|||
12 |
Rated current of over current trip |
A |
5 |
|||
13 |
Mechanical life |
second |
10000 |
|||
14 |
Allowable wear accumulative thickness of moving and static contacts |
mm |
3 |
|||
15 |
Rated current of over current release |
A |
5 |
|||
16 |
Current ratio of current transformer |
/ |
200/5 400/5 600/5 |
|||
17 |
Contact opening distance |
mm |
9±1 |
|||
18 |
Contact overtravel |
mm |
2±0.5 |
|||
19 |
Average opening speed |
m/s |
1.2±0.3 |
|||
20 |
Average closing speed |
m/s |
0.6±0.2 |
|||
21 |
Opening time |
ms |
≤40 |
|||
22 |
Closing time |
ms |
20~45 |
|||
23 |
Closing bounce time |
ms |
≤2 |
|||
24 |
Asynchrony of three phase closing and opening |
mm |
≤2 |
|||
25 |
Three phase circuit resistance |
μΩ |
≤80 Band isolation≤120 |