Superior Customizable Surge Arrester for Enhanced Voltage Protection Systems

Product Details
Customization: Available
Type: Power Source Arrester
Structure: Zinc Oxide Arrester
Still deciding? Get samples of US$ 35/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

OEM Services
The supplier provides OEM services for popular brands
Quality Assurance
The supplier provides quality assurance
Private Mold
The supplier has private mold
Product Certification
The supplier's products already have relevant certification qualifications, including:
CE
to see all verified strength labels (20)
  • Superior Customizable Surge Arrester for Enhanced Voltage Protection Systems
  • Superior Customizable Surge Arrester for Enhanced Voltage Protection Systems
  • Superior Customizable Surge Arrester for Enhanced Voltage Protection Systems
  • Superior Customizable Surge Arrester for Enhanced Voltage Protection Systems
  • Superior Customizable Surge Arrester for Enhanced Voltage Protection Systems
  • Superior Customizable Surge Arrester for Enhanced Voltage Protection Systems
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Certifications
  • Company Profile
Overview

Basic Info.

Model NO.
YH series
Installation
According to Customer Requirements
Application
AC/DC System/Power Plants/Substation
Size
According to Customer Requirements
Operation Voltage
3 - 36kv
Shape
According to Customer Requirements
Material
ZnO
Certification
ROHS, ISO9001, CCC
Brand
Chbeb
Customizable
OEM/According to Customer Requirements
Voltage Customizable
30kv 33kv 36kv
Transport Package
Pallet
Trademark
CHBEB
Origin
China
HS Code
8535400000
Production Capacity
50000 Pieces/Quarter

Product Description

Product Description

Introducing the Zinc Oxide Arrester from Beierbian Group Co., Ltd - a cutting-edge, fully sealed, and exceptionally dependable marvel in lightning protection technology for 10kV power distribution systems. This state-of-the-art device is expertly crafted with a zinc oxide valve column, fortified by upper and lower electrodes, all exquisitely encased in silicone rubber, offering unmatched features:

  1. This groundbreaking design brilliantly tackles and resolves the sealing challenges that have traditionally plagued arresters. By seamlessly integrating the core and jacket into one unified, compact structure, it eliminates any cavities that could potentially cause internal breathing issues, thereby ingeniously overcoming the technical obstacles related to moisture penetration in internal components.
  2. Featuring a robust core with an impressive capacity to withstand internal overvoltage, this arrester demonstrates exceptional resistance to aging, ensuring consistent performance and steadfast protection over the years.

Employing a specially designed valve plate in conjunction with refined core parameters, this device ensures that the core withstands challenges such as arc grounding, PT resonance, and a wide range of operational overvoltages. It operates with unparalleled reliability under line voltage, as well as enduring overvoltages of 2.5 to 3 times power frequency. Its voltage withstand duration exceeds international standards by 1 to 3 orders of magnitude, guaranteeing unrivaled safety and operational longevity.
Superior Customizable Surge Arrester for Enhanced Voltage Protection Systems

Detailed Photos

Superior Customizable Surge Arrester for Enhanced Voltage Protection Systems

Superior Customizable Surge Arrester for Enhanced Voltage Protection Systems
Superior Customizable Surge Arrester for Enhanced Voltage Protection Systems
Superior Customizable Surge Arrester for Enhanced Voltage Protection Systems
Superior Customizable Surge Arrester for Enhanced Voltage Protection Systems
Superior Customizable Surge Arrester for Enhanced Voltage Protection Systems
Superior Customizable Surge Arrester for Enhanced Voltage Protection Systems

Product Parameters

Main Characteristics Of Jacket Materials And Product Usage Environment:

Item

Unit

Norm

Shore Hardness A

/

60

Tensile Strength

mpa

≥35

Breaking Elongation

%

≥250

Oxygen Index

/

45

Resistivity

Ω.m

≥1×1013

Breakdown Strength

MV/m

≥25

Tracking

kV

4.5

Durability

Not less than 20 years

Working Environment:

Meticulously crafted to perform flawlessly in both indoor and outdoor settings;

Efficiently functions at altitudes reaching an impressive 3000 meters, ensuring reliability;

Designed to endure ambient temperatures from a frostbiting -40°C to a warm +60°C, guaranteeing versatility;

Adaptable to power supply frequencies ranging from a steady 48Hz to a dynamic 62Hz, offering consistent performance;

Maintains the power frequency voltage between terminals within ideal levels, ensuring optimal efficiency and longevity.

Built to withstand seismic activities up to 8 degrees, ensuring durability and stability.

Developed to resist outdoor wind velocities up to a robust 35 meters/second, promising resilience;

Note:

If faced with conditions beyond these standard operational parameters, consult with our experts for bespoke solutions.

Main Technical Parameters

Model

Nominal Voltage

(rms)

Rated Voltage OArrester

(rms)

Continuous Operating Voltage

(rms)

DC 1mA reference voltage
kV not less than

The residual voltage under nominal discharge current
kV (Crest) not greater than

Steep wave impact residual voltage
kV (Crest) not greater than

2ms square wave flow capacity
A

Operation Place

YH5WS-3.8/17

3

3.8

2.0

7.5

17.0

19.6

100

 

Distribution Type

YH5WS-5/15

3

5

4.0

7.5

15.0

17.3

150

YH5WS-7.6/30

6

7.6

4.0

15.0

15.0

34.5

100

YH5WS-10/30

6

10

8.0

15.0

30.0

34.6

150

YH5WS-12.7/50

10

12.7

10

26.0

50.0

57.5

100

YH5WS-16.5/50

10

16.5

12.7

26.0

50.0

57.5

100

YH5WS-17/50

10

17

13.6

26.0

50.0

57.5

150

YH5WS-17/45

10

17

13.6

25.0

45.0

/

250

YH10WS-17/45

10

17

13.6

25.0

45.0

/

400

YH5WZ-5/13.5

3

5

4.0

7.2

13.5

15.5

200

Power Station Type

YH5WZ-7.6/27

6

7.6

4.0

14.4

27.0

31.0

150

YH5WZ-10/27

6

10

8.0

14.4

27.0

31.0

200

YH5WZ-42/134

35

42

23.4

73

134

154

150

YH5WZ-12.7/45

10

12.7

6.6

24.0

45.0

51.8

150

YH5WZ-16.5/45

10

16.5

13.2

24.0

45.0

51.8

150

YH5WZ-17/45

10

17

13.6

24.0

45.0

51.8

200

YH5WZ-51/134

35

51

40.8

73.0

134

154

400

YH10WZ-17/45

10

17

13.6

24.0

45.0

51.8

200

YH10WZ-51/134

35

51

40.8

73.0

134

154

400

YH5WR-5/13.5

3

5

4.0

7.2

13.5

/

400

Capacitive Type

YH5WR-7.6/27

6

7.6

4.0

13.8

27.0

/

400

YH5WR-10/27

6

10

8.0

14.4

27.0

/

400

YH5WR-12.7/45

10

12.7

6.6

23.0

45.0

/

400

YH5WR 17/45

10

17

13.6

24.0

45.0

/

400

YH5WX-51/134

35

51

40.8

73

134.0

154

400

Line type

YH1.5W-30/80

35

30

24

44

80.0

/

600

Neutral Type

Note: Featuring a durable Polymeric construction to enhance longevity

Model

Nominal Voltage

(rms)

Rated Voltage OArrester

(rms)

Continuous Operating Voltage

(rms)

DC 1mA Reference Voltage
kV Not Less Than

The Residual Voltage Under Nominal Discharge Current
kV (Crest)
Not Greater Than

Steep Wave Impact Residual Voltage
kV (Crest)
Not Greater Than

2ms Square Wave Flow Capacity
A

Operation Place

Y5WS-5/15

3

5

4.0

7.5

15.0

17.3

150

Distribution Type

Y5WS-7.6/30

6

7.6

4.0

15.0

15.0

34.5

100

Y5WS-10/30

6

10

8.0

15.0

30.0

34.6

150

Y5WS-12.7/50

10

12.7

10

26.0

50.0

57.5

100

Y5WS-16.5/50

10

16.5

12.7

26.0

50.0

57.5

100

Y5WS-17/50

10

17

13.6

26.0

50.0

57.5

150

Y5WZ-5/13.5

3

5

4.0

7.2

13.5

15.5

200

Power Station Type

Y5WZ-7.6/27

6

7.6

4.0

14.4

27.0

31.0

150

Y5WZ-10/27

6

10

8.0

14.4

27.0

31.0

200

Y5WZ-42/134

35

42

23.4

73

134

154

150

Y5WZ-12.7/45

10

12.7

6.6

24.0

45.0

51.8

150

Y5WZ-16.5/45

10

16.5

13.2

24.0

45.0

51.8

150

Y5WZ-17/45

10

17

13.6

24.0

45.0

51.8

200

Y5WZ-51/134

35

51

40.8

73.0

134

154

400

Y5WR-5/13.5

3

5

4.0

7.2

13.5

/

400

Capacitive Type

Y5WR-7.6/27

6

7.6

4.0

13.8

27.0

/

400

Y5WR-10/27

6

10

8.0

14.4

27.0

/

400

Y5WR-12.7/45

10

12.7

6.6

23.0

45.0

/

400

Y5WR-17/45

10

17

13.6

24.0

45.0

/

400

Y1.5W-0.28/1.3

0.22

0.28

0.24

0.6

1.3

/

75

Low Voltage

Y1.5W-0.5/2.6

0.38

0.5

0.24

1.2

2.6

/

75

Note:Porcelain

Model

 

Nominal Voltage
(Valid values)

 

Rated Voltage Of Arrester
(Valid values)

 

The Wave Front

Steepness Of The Shock Discharge

 

DC 1mA Reference Voltage

kV Not Less Than

 

1.2/50 Impulse Discharge Voltage

Not Greater Than

 

Wavefront Impulse

Discharge Voltage

 

kV Not Greater Than

The Residual Voltage Under Nominal Discharge

Current 8/20μs

 

kV Not Greater Than

 

2000μs Square

Wave Flow Capacity

 

4/10μs Impulse

Current Capacity

Y5CS-7.6/27

6

7.6

63

16

35

43.8

27

75

25

Y5CZ-7.6/24

6

7.6

63

16

30

37.5

24

150

40

Y5CS-12.7/45

10

12.7

106

26

50

62.5

45

75

25

Y5CS-12.7/41

10

12.7

106

26

45

56.5

41

200

40

Y5CZ-42/124

35

42.0

343

82

134

168

124

200

40

Note: Incorporates Porcelain Series Gap specification for optimal functionality

Installation

(1) Before installation, check the nameplate to confirm that the arrester's system rated voltage matches the system voltage at the installation site;

(2) Offers versatility with both suspension and vertical installation options. Avoid using the arrester as a load-supporting insulator for vertical setup;

(3) Ensure the lead wire is appropriately sized to optimize protection efficiency and prevent stress on the equipment.

Test

  • For optimal operational reliability, conduct preventive tests every 4-5 years, focusing on U1mA measurement at both terminals of the DC 1mA arrester.
  • Before installation, confirm that the U1mA voltage is no less than 97% of the original factory value and duly record this data for reference.
  • During preventive maintenance, ensure that the U1mA voltage remains above 26kV to maintain efficiency.
  • Note: Reduce harmonic components in the DC power supply during tests to avoid inaccurate U1mA readings due to poor waveforms.
  • The innovative 10kV synthetic insulated zinc oxide arrester for power distribution has passed intensive lab tests, demonstrating consistent outdoor line voltage performance over 15 months. These results confirm the jacket's superior quality, the arrester's structural reliability, and the core's steadfast stability. Coupled with annual performance data from 2,000 units, the product ensures exceptional protection, minimized failure rates, and maintenance-free operation throughout its lifecycle.Superior Customizable Surge Arrester for Enhanced Voltage Protection Systems
Certifications

Superior Customizable Surge Arrester for Enhanced Voltage Protection Systems

Company Profile

Superior Customizable Surge Arrester for Enhanced Voltage Protection Systems

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier