Medium Voltage Load Break Disconnect Switch for High-Voltage Outdoor Use

Product Details
Customization: Available
Type: 10kv/12kv/15kv
Structure: According to Customer Requirements
Still deciding? Get samples of $ !
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

OEM Services
The supplier provides OEM services for popular brands
Quality Assurance
The supplier provides quality assurance
Private Mold
The supplier has private mold
Product Certification
The supplier's products already have relevant certification qualifications, including:
CE
to see all verified strength labels (20)
  • Medium Voltage Load Break Disconnect Switch for High-Voltage Outdoor Use
  • Medium Voltage Load Break Disconnect Switch for High-Voltage Outdoor Use
  • Medium Voltage Load Break Disconnect Switch for High-Voltage Outdoor Use
  • Medium Voltage Load Break Disconnect Switch for High-Voltage Outdoor Use
  • Medium Voltage Load Break Disconnect Switch for High-Voltage Outdoor Use
  • Medium Voltage Load Break Disconnect Switch for High-Voltage Outdoor Use
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Certifications
Overview

Basic Info.

Model NO.
(H)GWBEB
Installation
Outdoor High-voltage
Operation
Manual/Electric/Pneumatic/Hydraulic
Grounding Mode
According to Customer Requirements
Movement Mode
According to Customer Requirements
Number of Poles
According to Customer Requirements
Grounding
According to Customer Requirements
Series
Two
Run
According to Customer Requirements
Switching Mode
According to Customer Requirements
Common Model
Gw9
Structure of Operating
According to Customer Requirements
Certification
ISO, RoHS, CE
Brand
Chbeb
Customizable
OEM/According to Customer Requirements
Transport Package
Standard Shipping Packing
Specification
45*55*38mm
Trademark
CHBEB
Origin
China
HS Code
853530900
Production Capacity
5000 PCS/Quarter

Product Description

Medium Voltage Load Break Disconnect Switch for High-Voltage Outdoor Use
Product Description

(H)GWBEB, a meticulously engineered type of outdoor high-voltage isolation switch—often referred to as a disconnect switch—is purpose-built for 10(12, 15, 24)kV high voltage power transmission and distribution networks. This switch facilitates the seamless opening and closing of single-phase or three-phase circuits, efficiently managing operations without load yet with voltage present.

Designed specifically for single-phase use within three-phase line systems, this switch boasts a straightforward architecture, delivering cost savings and user-friendly operation. Offering a range of rated currents including 200, 400, 600, 800, 1000, and 1250 amps, these switches are composed of a robust base, durable post insulators, conductive components, and a precise mechanical section. The innovative gate knife structure ensures effective circuit management for opening and closing activities. Each phase is equipped with a dual-blade gate knife, supported by external compression springs on both sides. The contact pressure necessary for optimal operation is adjustable via the spring height. An insulated hook stick is employed for operational actions, ensuring ease of use, and a self-locking device ensures additional safety.

Working Environment:

Altitude not exceeding 1000 meters is ideal for optimal performance.

The ambient temperature is critical: it should not exceed +40°C at its highest, nor drop below -30°C at its lowest.

Outdoor wind conditions should remain under a speed of 35 meters/second.

The location should withstand a seismic intensity not greater than 8 degrees, and must be free from frequent severe vibrations, for stability and reliability.

The installation site must be clear of harmful gases, chemical deposits, salt mist, dust, dirt, and any other explosive or corrosive substances that could compromise the switch's insulation and conductivity.

Note:

WHEN NORMAL USE CONDITIONS AS SPECIFIED ARE EXCEEDED, USERS CAN ARRANGE A CONSULTATION WITH THE COMPANY TO DISCUSS CUSTOMIZED SOLUTIONS.

Installation, Use and Adjustment

Pre-installation work

  1. Carefully remove all dust and dirt from the components, ensuring that the surface of the insulating porcelain bottle is thoroughly wiped.
  2. Scrub the wiring surface of the ground screw meticulously to ensure proper conductivity.
  3. Apply a protective layer of industrial Vaseline to all rotating parts and contact areas to ensure smooth operation and longevity.
  4. Verify the contact surface and adjust the compression spring height to meet the pressure standards outlined in Table II, ensuring optimal contact pressure.
  5. This switch is exclusively designed for hoisting use and is intended for integration with transformers on the line, ensuring seamless connectivity.
  6. The switch is rated at 200-400 ampere hours, typically requiring the use of three mounting holes. For a 600-1000A rating, three mounting holes are essential.

Conduct annual checks of the following switch components:
Thoroughly clean dirt from conductive parts, contact surfaces, and the insulating porcelain bottles to maintain efficiency.

Inspect all components for any signs of damage, particularly focusing on the insulating porcelain bottle for potential damage or cracks.

Ensure the contact surface of the conductive part remains impeccable.


Medium Voltage Load Break Disconnect Switch for High-Voltage Outdoor Use

Detailed Photos

Medium Voltage Load Break Disconnect Switch for High-Voltage Outdoor Use
Medium Voltage Load Break Disconnect Switch for High-Voltage Outdoor Use
Medium Voltage Load Break Disconnect Switch for High-Voltage Outdoor Use
Medium Voltage Load Break Disconnect Switch for High-Voltage Outdoor Use


Medium Voltage Load Break Disconnect Switch for High-Voltage Outdoor Use
Medium Voltage Load Break Disconnect Switch for High-Voltage Outdoor Use

Medium Voltage Load Break Disconnect Switch for High-Voltage Outdoor Use
Medium Voltage Load Break Disconnect Switch for High-Voltage Outdoor Use
Medium Voltage Load Break Disconnect Switch for High-Voltage Outdoor Use
Medium Voltage Load Break Disconnect Switch for High-Voltage Outdoor Use
Medium Voltage Load Break Disconnect Switch for High-Voltage Outdoor Use
Medium Voltage Load Break Disconnect Switch for High-Voltage Outdoor Use
Medium Voltage Load Break Disconnect Switch for High-Voltage Outdoor Use
Medium Voltage Load Break Disconnect Switch for High-Voltage Outdoor Use
Medium Voltage Load Break Disconnect Switch for High-Voltage Outdoor Use
Medium Voltage Load Break Disconnect Switch for High-Voltage Outdoor Use
Medium Voltage Load Break Disconnect Switch for High-Voltage Outdoor Use
Medium Voltage Load Break Disconnect Switch for High-Voltage Outdoor Use

Product Parameters

The main technical parameters

Table I

Model

Rated voltage
kV

 

Rated current
A

kA

 

10 seconds thermal stable current
kA

peak

Valid values

 

(H)GW

 

10

12

15

200

5

9

5

400

21

15

10

600

35

25

14

630

35

25

14

800

35

25

14

1000

50

35

20

Contact force parameters

Table II

Model

Rated current(A)

contact pressure(kgf)

(H)GW

5

9

21

15

35

25

35

25

35

25

50

35

Certifications

Medium Voltage Load Break Disconnect Switch for High-Voltage Outdoor UseMedium Voltage Load Break Disconnect Switch for High-Voltage Outdoor Use

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier