Medium Voltage Load Break Isolation Switch for Outdoor Disconnect Applications

Product Details
Customization: Available
Type: 10kv/12kv/15kv
Structure: According to Customer Requirements
Still deciding? Get samples of $ !
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

OEM Services
The supplier provides OEM services for popular brands
Quality Assurance
The supplier provides quality assurance
Private Mold
The supplier has private mold
Product Certification
The supplier's products already have relevant certification qualifications, including:
CE
to see all verified strength labels (20)
  • Medium Voltage Load Break Isolation Switch for Outdoor Disconnect Applications
  • Medium Voltage Load Break Isolation Switch for Outdoor Disconnect Applications
  • Medium Voltage Load Break Isolation Switch for Outdoor Disconnect Applications
  • Medium Voltage Load Break Isolation Switch for Outdoor Disconnect Applications
  • Medium Voltage Load Break Isolation Switch for Outdoor Disconnect Applications
  • Medium Voltage Load Break Isolation Switch for Outdoor Disconnect Applications
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Certifications
Overview

Basic Info.

Model NO.
(H)GWBEB
Installation
Outdoor High-voltage
Operation
Manual/Electric/Pneumatic/Hydraulic
Grounding Mode
According to Customer Requirements
Movement Mode
According to Customer Requirements
Number of Poles
According to Customer Requirements
Grounding
According to Customer Requirements
Series
Two
Run
According to Customer Requirements
Switching Mode
According to Customer Requirements
Common Model
Gw9
Structure of Operating
According to Customer Requirements
Certification
ISO, RoHS, CE
Brand
Chbeb
Customizable
OEM/According to Customer Requirements
Transport Package
Standard Shipping Packing
Specification
45*55*38mm
Trademark
CHBEB
Origin
China
HS Code
853530900
Production Capacity
5000 PCS/Quarter

Packaging & Delivery

Package Size
45.00cm * 55.00cm * 38.00cm
Package Gross Weight
20.000kg

Product Description

Medium Voltage Load Break Isolation Switch for Outdoor Disconnect Applications
Product Description

(H)GWBEB type outdoor high-voltage isolation switch, renowned in the industry as an isolation disconnect switch, is masterfully engineered for deployment on 10(12, 15, 24)kV high voltage power transmission and distribution lines. It is designed to seamlessly open and close single-phase or three-phase circuits without any load but with voltage present, ensuring unparalleled efficiency and reliability in power management.

This versatile switch is crafted for single-phase use within three-phase line systems, boasting a straightforward yet highly effective structure, remarkable cost-efficiency, and user-friendly operation. Available in rated currents of 200, 400, 600, 800, 1000, and 1250 amps, these switches are composed of a robust base, durable post insulators, conductive elements, and a mechanical section. The ingenious gate knife design facilitates efficient circuit opening and closing, with each phase's gate knife featuring two conductive blades and external compression springs for optimal performance. By adjusting the spring height, the required contact pressure for the switch's gate knife is achieved, ensuring a secure and reliable operation. The switch is operated with an insulated hook stick for ease of opening and closing, and incorporates a self-locking device for added safety.

Working Environment:

Altitude not exceeding 1000 meters; ideal for versatile geographical locations.

Ambient temperature: maximum not above +40°C; minimum not below -30°C, ensuring adaptability to various climates.

Outdoor wind speed not exceeding 35 meters/second, providing resilience against strong winds.

Seismic intensity not exceeding 8 degrees; the installation site should maintain stability without frequent severe vibrations.

The installation site must be free from gases, chemical deposits, salt mist, dust, dirt, or other harmful explosive or corrosive mediums that could seriously compromise the switch's insulation and conductivity.

Note:

WHEN THE ABOVE NORMAL USE CONDITIONS ARE EXCEEDED, USERS ARE ENCOURAGED TO NEGOTIATE WITH THE COMPANY FOR CUSTOMIZED SOLUTIONS.

 

Installation, Use and Adjustment

Pre-installation work

  1. Thoroughly remove dust and dirt from all parts, ensuring a pristine surface on the insulating porcelain bottle for optimal performance.
  2. Meticulously scrub the wiring surface of the ground screw, ensuring reliable electrical connectivity.
  3. Apply a protective layer of industrial Vaseline to the rotating parts and contact areas, enhancing longevity and operational smoothness.
  4. Inspect the contact surface meticulously and adjust the compression spring height to ensure the contact pressure aligns with Table II, guaranteeing reliable operation.
  5. This switch is exclusively designed for hoisting applications and is intended to be used in conjunction with transformers on the line, ensuring robust and efficient power distribution.
  6. The rated current of this switch spans 200-400 ampere hours, typically employing three mounting holes, while the 600-1000A variants also utilize three mounting holes for secure installation.

Perform a comprehensive annual check of the following switch components:
Efficiently remove dirt from conductive parts, contact surfaces, and the insulating porcelain bottle surfaces to maintain optimal performance.

Inspect all components for any signs of damage, with particular attention to the insulating porcelain bottle, ensuring it is free from damage and cracks.

Assess whether the contact surface of the conductive part remains in good condition, ensuring continued reliable operation.


Medium Voltage Load Break Isolation Switch for Outdoor Disconnect Applications

Detailed Photos

 

Medium Voltage Load Break Isolation Switch for Outdoor Disconnect Applications
Medium Voltage Load Break Isolation Switch for Outdoor Disconnect Applications
Medium Voltage Load Break Isolation Switch for Outdoor Disconnect Applications
Medium Voltage Load Break Isolation Switch for Outdoor Disconnect Applications


Medium Voltage Load Break Isolation Switch for Outdoor Disconnect Applications
Medium Voltage Load Break Isolation Switch for Outdoor Disconnect Applications

Medium Voltage Load Break Isolation Switch for Outdoor Disconnect Applications
Medium Voltage Load Break Isolation Switch for Outdoor Disconnect Applications
Medium Voltage Load Break Isolation Switch for Outdoor Disconnect Applications
Medium Voltage Load Break Isolation Switch for Outdoor Disconnect Applications
Medium Voltage Load Break Isolation Switch for Outdoor Disconnect Applications
Medium Voltage Load Break Isolation Switch for Outdoor Disconnect Applications
Medium Voltage Load Break Isolation Switch for Outdoor Disconnect Applications
Medium Voltage Load Break Isolation Switch for Outdoor Disconnect Applications
Medium Voltage Load Break Isolation Switch for Outdoor Disconnect Applications
Medium Voltage Load Break Isolation Switch for Outdoor Disconnect Applications
Medium Voltage Load Break Isolation Switch for Outdoor Disconnect Applications
Medium Voltage Load Break Isolation Switch for Outdoor Disconnect Applications

 

Product Parameters

The main technical parameters

Table I

Model

Rated voltage
kV

 

Rated current
A

kA

 

10 seconds thermal stable current
kA

peak

Valid values

 

(H)GW

 

10

12

15

200

5

9

5

400

21

15

10

600

35

25

14

630

35

25

14

800

35

25

14

1000

50

35

20

Contact force parameters

Table II

Model

Rated current(A)

contact pressure(kgf)

(H)GW

5

9

21

15

35

25

35

25

35

25

50

35

Certifications

Medium Voltage Load Break Isolation Switch for Outdoor Disconnect ApplicationsMedium Voltage Load Break Isolation Switch for Outdoor Disconnect Applications