Medium Voltage Isolation Load Break Disconnect Switch for Outdoor Use, Durable, Reliable, OEM Customizable

Product Details
Customization: Available
Type: 10kv/12kv/15kv
Structure: According to Customer Requirements
Still deciding? Get samples of $ !
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

OEM Services
The supplier provides OEM services for popular brands
Quality Assurance
The supplier provides quality assurance
Private Mold
The supplier has private mold
Product Certification
The supplier's products already have relevant certification qualifications, including:
CE
to see all verified strength labels (20)
  • Medium Voltage Isolation Load Break Disconnect Switch for Outdoor Use, Durable, Reliable, OEM Customizable
  • Medium Voltage Isolation Load Break Disconnect Switch for Outdoor Use, Durable, Reliable, OEM Customizable
  • Medium Voltage Isolation Load Break Disconnect Switch for Outdoor Use, Durable, Reliable, OEM Customizable
  • Medium Voltage Isolation Load Break Disconnect Switch for Outdoor Use, Durable, Reliable, OEM Customizable
  • Medium Voltage Isolation Load Break Disconnect Switch for Outdoor Use, Durable, Reliable, OEM Customizable
  • Medium Voltage Isolation Load Break Disconnect Switch for Outdoor Use, Durable, Reliable, OEM Customizable
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Certifications
Overview

Basic Info.

Model NO.
(H)GWBEB
Installation
Outdoor High-voltage
Operation
Manual/Electric/Pneumatic/Hydraulic
Grounding Mode
According to Customer Requirements
Movement Mode
According to Customer Requirements
Number of Poles
According to Customer Requirements
Grounding
According to Customer Requirements
Series
Two
Run
According to Customer Requirements
Switching Mode
According to Customer Requirements
Common Model
Gw9
Structure of Operating
According to Customer Requirements
Certification
ISO, RoHS, CE
Brand
Chbeb
Customizable
OEM/According to Customer Requirements
Transport Package
Standard Shipping Packing
Specification
45*55*38mm
Trademark
CHBEB
Origin
China
HS Code
853530900
Production Capacity
5000 PCS/Quarter

Packaging & Delivery

Package Size
45.00cm * 55.00cm * 38.00cm
Package Gross Weight
20.000kg

Product Description

Medium Voltage Isolation Load Break Disconnect Switch for Outdoor Use, Durable, Reliable, OEM Customizable
Product Description

Introducing our (H)GWBEB type outdoor high-voltage isolation switch, also known as the isolation disconnect switch. This advanced solution is meticulously designed for high voltage power transmission and distribution lines, capable of managing 10(12, 15, 24)kV operations. It expertly handles the opening and closing of single-phase or three-phase circuits, delivering unparalleled performance even with voltage present yet no load.

This switch is tailored for seamless single-phase operation within three-phase line systems. Boasting a straightforward structure, it promises cost-effectiveness and ease of use. Choose from a range of rated currents: 200, 400, 600, 800, 1000, and 1250 amps. Each switch is composed of a robust base, post insulators, conductive elements, and a precision mechanical section. Employing a gate knife mechanism, the switch ensures efficient circuit operations. Each phase features two conductive blades and external compression springs that can be adjusted for optimal contact pressure. Operated via an insulated hook stick, the switch includes a self-locking device, enhancing its safety and reliability.

Working Environment:

Designed to perform flawlessly at altitudes not exceeding 1000 meters;

The switch can withstand ambient temperatures ranging from a chilly -30°C to a warm +40°C;

It can endure outdoor wind speeds reaching up to 35 meters/second;

Engineered to withstand seismic intensities up to 8 degrees, provided the location is free from frequent severe vibrations.

Installations should be in environments free from gases, chemical deposits, salt mist, dust, dirt, or any explosive or corrosive substances that could compromise insulation and conductivity.

Note:

Should any of the above standard conditions be exceeded, a consultation with our company is advocated for optimal performance solutions.

 

Installation, Use and Adjustment

Pre-installation work

  1. Meticulously remove dust and dirt from all parts, ensuring to thoroughly clean the insulating porcelain bottle's surface.
  2. Ensure the ground screw's wiring surface is pristine by scrubbing.
  3. Apply a protective layer of industrial Vaseline to all rotating and contact areas for smooth operation.
  4. Inspect the contact surfaces and fine-tune the compression spring's height to ensure the contact pressure is in accordance with Table II specifications.
  5. This switch is specifically designed for hoisting and should be used in conjunction with a transformer along the line.
  6. The rated current for this switch spans from 200 to 400 ampere hours, generally utilizing three mounting holes, while 600-1000A configurations also employ three mounting holes.

Conduct an annual inspection of the following switch components:
Diligently remove any accumulated dirt from the conductive parts, the contact surfaces, and the insulating porcelain bottles' exterior.

Thoroughly check all components for any damage, with a particular focus on identifying any harm or cracks in the insulating porcelain bottle.

Ensure that the contact surfaces of the conductive parts maintain optimal conditions.


Medium Voltage Isolation Load Break Disconnect Switch for Outdoor Use, Durable, Reliable, OEM Customizable

Detailed Photos

 

Medium Voltage Isolation Load Break Disconnect Switch for Outdoor Use, Durable, Reliable, OEM Customizable
Medium Voltage Isolation Load Break Disconnect Switch for Outdoor Use, Durable, Reliable, OEM Customizable
Medium Voltage Isolation Load Break Disconnect Switch for Outdoor Use, Durable, Reliable, OEM Customizable
Medium Voltage Isolation Load Break Disconnect Switch for Outdoor Use, Durable, Reliable, OEM Customizable


Medium Voltage Isolation Load Break Disconnect Switch for Outdoor Use, Durable, Reliable, OEM Customizable
Medium Voltage Isolation Load Break Disconnect Switch for Outdoor Use, Durable, Reliable, OEM Customizable

Medium Voltage Isolation Load Break Disconnect Switch for Outdoor Use, Durable, Reliable, OEM Customizable
Medium Voltage Isolation Load Break Disconnect Switch for Outdoor Use, Durable, Reliable, OEM Customizable
Medium Voltage Isolation Load Break Disconnect Switch for Outdoor Use, Durable, Reliable, OEM Customizable
Medium Voltage Isolation Load Break Disconnect Switch for Outdoor Use, Durable, Reliable, OEM Customizable
Medium Voltage Isolation Load Break Disconnect Switch for Outdoor Use, Durable, Reliable, OEM Customizable
Medium Voltage Isolation Load Break Disconnect Switch for Outdoor Use, Durable, Reliable, OEM Customizable
Medium Voltage Isolation Load Break Disconnect Switch for Outdoor Use, Durable, Reliable, OEM Customizable
Medium Voltage Isolation Load Break Disconnect Switch for Outdoor Use, Durable, Reliable, OEM Customizable
Medium Voltage Isolation Load Break Disconnect Switch for Outdoor Use, Durable, Reliable, OEM Customizable
Medium Voltage Isolation Load Break Disconnect Switch for Outdoor Use, Durable, Reliable, OEM Customizable
Medium Voltage Isolation Load Break Disconnect Switch for Outdoor Use, Durable, Reliable, OEM Customizable
Medium Voltage Isolation Load Break Disconnect Switch for Outdoor Use, Durable, Reliable, OEM Customizable

 

Product Parameters

The main technical parameters

Table I

Model

Rated voltage
kV

 

Rated current
A

kA

 

10 seconds thermal stable current
kA

peak

Valid values

 

(H)GW

 

10

12

15

200

5

9

5

400

21

15

10

600

35

25

14

630

35

25

14

800

35

25

14

1000

50

35

20

Contact force parameters

Table II

Model

Rated current(A)

contact pressure(kgf)

(H)GW

5

9

21

15

35

25

35

25

35

25

50

35

Certifications

Medium Voltage Isolation Load Break Disconnect Switch for Outdoor Use, Durable, Reliable, OEM CustomizableMedium Voltage Isolation Load Break Disconnect Switch for Outdoor Use, Durable, Reliable, OEM Customizable